My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FAIRMONT
>
975
>
2300 - Underground Storage Tank Program
>
PR0231331
>
COMPLIANCE INFO_2015-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2023 2:14:17 PM
Creation date
6/3/2020 9:44:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015-2018
RECORD_ID
PR0231331
PE
2351
FACILITY_ID
FA0000513
FACILITY_NAME
LODI MEMORIAL HOSPITAL
STREET_NUMBER
975
Direction
S
STREET_NAME
FAIRMONT
STREET_TYPE
AVE
City
LODI
Zip
95240
APN
03107039
CURRENT_STATUS
01
SITE_LOCATION
975 S FAIRMONT AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231331_975 S FAIRMONT_2015-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
286
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RE4, ,AV <br /> OCT 312017 <br /> J <br /> Maximize protection with a vacuum rr 4 <br /> monitored secondary containment _ <br /> system. <br /> A Secondary Containment Vacuum Features and Benefits Facilitates periodic operability testing <br /> Sensing System for use with Veeder- Satisfy Requirernows Leverage Existing Veeder-Root Syslerns <br /> Root's ATG Systems. The Secondary Certified to meet Caiifontfa's requirement for uses SCP as the vacuum source:and works with <br /> s<eendary monitoring for tanks and lines Rte(jacket and FE SIPS <br /> / <br /> Containment— Sensing (SCVS) as mired s by A8 2481 Installs in the STP sump and connects to the <br /> System is designed to detect leaks in double- Satisfies the requirements for Class I Leak console via intrinsically safe wiring <br /> walled tanks and piping systems while Detection asdefined bythe European Able to share wiring conduit with other <br /> helping to contain a release of product while Standard EN 13160.2 Veeder-Rootintrir,Aysafe(IS)probesand <br /> • 3rd Darty,National dWd<Group and LG113 sensors including sunt or line leak sensors <br /> ander vacuum.111e system consists of: listed <br /> • Interlaces to the Smart Sensor Interface with <br /> • Vacuum Sensors,connected to Lank, Reduce Fxposure to Risk <br /> Embedded o positive shutModde <br /> sunt or piping interstices .Alamts when vactaLun cannot be maintained Provides for positive shut down of pressurized <br /> p p p ° or when replenish tate exceeds 85 liters per hour lines when required <br /> • A Submersible Turbine Pump(STP), • Simple installation,no need to mm with brine <br /> to provide a source of vacuum tthe ssystem <br /> ov da� �fieri liquid s detected in <br /> • A Smart Sensor Interface with Embedded <br /> Pressure Module in a TLS-350 Operating Temperature Rating: Console Capability <br /> Monitoring System -25 degrees C to+70 degrees C The Vacuum Sensor is compatible with <br /> the following consoles: <br /> The Vacuum Sensor is interfaced to Veeder- Cable Length: Console <br /> 8 feat TLS-350R/EMC wlBIH' <br /> Root's TLS-350 Monitoring System via TL.S-350 Plus/EMC Enhanced' <br /> intrinsically safe wiring to provide system Sensor Dimensions' TLS-350/EMC' <br /> status,replenish rate,alaml,and diagnostic 5"high x 5"wide 2"deep `Upgrade Note:The Vacuum Sensor System requires <br /> information. the console to have version 24C software(or greater) <br /> along with an ECPU2 or ECRJ w/NVMEM 1 board. <br /> Standard Models <br /> Vacuum Sensor Kits are available in a variety veeder-Root;P/N Description <br /> of models: 330020-467 4 Vacuum Sensor K t'for steel tank <br /> 330020-468,-469,-470,-471 4 Vacuum Sensor Kit'for fiberglass tanks(4',6',8',10') <br /> 330020-4864 Vacuum Sensor Kit`for no tank <br /> • For monitoring double-walled piping 330020-472 3 Vacuum Sensor tat'for steel tank <br /> 330020-473,-474,-475,-476 3 Vacuum Sensor Kit'for fiberglass tanks(4',6',8',10') _ <br /> and sump interstices331020-485___ ____ _�3 Vacuum Sensor Kit'for no tank <br /> 1m2Q, <br /> • For monitoring double-walled steel tank 3379 -2 vacuum SensorKit'for steel tank <br /> interstices(see back page) 330020-481,-482,-483,-484 2 Vacuum Sensor Kit'for fiberglass tanks(4',6',8',10') <br /> 330020-480 2 Vacuum Sensor Kit'for no tank <br /> • For double-walled fiberglass tanks 33020-495 1 vacuum Sensor Kir for no tank ^;:= <br /> 857280-100 _ Vacuum Sensor for piping&sumps <br /> These kits differ in the number of vacuum 857280-200 _ _vacuum Sensor for steel tanks <br /> 857280--301,-302,-303,-304 __Vacuum Sensor for fiberglass tanks(4',6',8',10) _ <br /> sensors and the configuration of associated 330020-448 Mounting <br /> liquid sensors.An inline lit mounted liquid 332217-001 Heliefyv eAssembly <br /> 332250-001 Smart Sensor w/Embedded Pressure Sensor Module(7 Channet)" <br /> sensor is used for Vacuum Sensors M <br /> monitoring piping and sumps. An external Accessories Part Description Quantity/Length Part Number <br /> 1/4"NPT Barbed Fittings 3 330020-487 <br /> liquid sensor(to be installed in the secondary 1/4"NPT Barbed Fittings 15 330020-488 <br /> space at the bottom of the tank)is provided 1/4"NFT Barbedttings Fi25 330020-489 <br /> with one of the Vacuum Sensors in the steel Barbed Tee 1 ` �_ 57sooa`657 <br /> Vacuum Hose 25' 25' 332310-001 <br /> and fiberglass tank kits to monitor the tank. Vacuum Hose 50�__- — -sa -— — 332310-002 <br /> Vacuum Hose 100'_ 100' 332310-003 <br /> 3-Way Ball Vafve 1 576008.649 <br /> Schrader Vance Barbed Fitting3 �_ 33020-496 <br /> Schrader Valve Barbed Fitting 15 330020.497 <br /> ' Ms include mounting bracket,6'of vacuum hose.relief valve asWnbty(if requrect and the appropriate number of liquid sensors, <br /> 3-way ball v*es,barbed fittings and hose clamps so that each vacuum sensor can mentor a single tarns,sump ar piping interstices. <br /> The Vacuum Sensing System requires one 7 channel Smad Sensor Interface vnlh Embedded Pressure Module.8 cannel Smar. <br /> Sonscr Modules Wn 329356-W4)can be used for Vac:un Sensors tight and above. <br /> For more information call: 1-888-561-7942 <br />
The URL can be used to link to this page
Your browser does not support the video tag.