Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FAIRMONT
>
975
>
2300 - Underground Storage Tank Program
>
PR0231331
>
COMPLIANCE INFO_2015-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2023 2:14:17 PM
Creation date
6/3/2020 9:44:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015-2018
RECORD_ID
PR0231331
PE
2351
FACILITY_ID
FA0000513
FACILITY_NAME
LODI MEMORIAL HOSPITAL
STREET_NUMBER
975
Direction
S
STREET_NAME
FAIRMONT
STREET_TYPE
AVE
City
LODI
Zip
95240
APN
03107039
CURRENT_STATUS
01
SITE_LOCATION
975 S FAIRMONT AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231331_975 S FAIRMONT_2015-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
286
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Maximize protection with a vacuum <br /> monitored secondary containments <br /> system. <br /> A Secondary Containment Vacuum Features and Benefits Facilitates periodic operability testing <br /> Sensing System for use with V(eedetii. Satisfy Requirements Leverage Existing Veeder-Root Systems <br /> Root's ATG Systems. The Secondary ' Certified tomee%airfomiArequiremanfor y rY a»tUses STP as the vacuum some and works with <br /> secondary <br /> Containment Vacuum Sensing (SCVS) se requiredr moriknring For tanks and lines Jacket and FE STPs <br /> System is designed to detect leaks in double- . �es the requirements for Class I leak consby AB 2481 . ole <br /> v the STP Sump and connects to the <br /> walled tanks and piping systems while Detection asdefined bythe European C0�0�viaintrinsi�lly wrmrg <br /> helping to contain a release of product while Standard EN 13160.2 . Able to share wrong condutt with other <br /> p g P Veeder-Root uurutsically safe(IS)probes and <br /> 3rd Party National Work Group and L.G113 <br /> under vacuum.The system consists of: lid settsoisincluding sump orline leaks�sors <br /> • Intel to the Stnan Sensor Interface with <br /> • Vacuum Sensors,connected to tank, Reduce Exposure to Riskstem a'rrm when liquid is de—ed in Embedded Pressure Module <br /> Alarms when vacuum carrot be maintair ied • Provides for positive shut down of pressurized <br /> sump or piping interstices or when re• plenish rate oweeds85liters perhour when• A Submersible Turbine Pump(STP), � �Supple installation,The syn,no need to mess with brine <br /> L <br /> to provide a source of vacuum the secondary spoe <br /> • A Smart Sensor Interface with Embedded <br /> Pressure Module in a TLS-350 Operating Temperature Rating: Console Capability <br /> Monitoring System -25 degrees C to+70 degrees C The Vacuum Sensor is compatible with <br /> the following consoles: <br /> The Vacuum Sensor is interfaced to Veeder- Cable Length: Console <br /> 8 feet TLS-350R/EMC w/BIR' <br /> Root's TLS-350 Monitoring System via TLS-350 Plus/EMC Enhanced` <br /> intrinsically safe wiring to provide system Sensor Dimensions: TLS-350/EMC• <br /> status,replenish rate,alarm,and diagnostic 5"high x 5"w de 2"deep Upgrade Note:The Vacuum Sensor System requires <br /> the console to have version 240 software(or greater) <br /> information. along with an ECPU2 or ECPU w/NVMEM 1 board. <br /> Standard Models <br /> Vacuum Sensor Kits are available in a variety VeedeMtoot PM Deser"on <br /> of models: 330020-467 4 Vacuum Sensor Kit'for steel tank <br /> 330020468,469,470,471 4 Vacuum Sensor Kit'for fiberglass tanks(4',6',8',10') <br /> 330020486 4 Vacuum Sensor Kit'for no tank <br /> • For monitoring double-walled piping 330020472 3 Vacuum Sensor Kt'for steel tank <br /> 330020-473,474,475,-476 3 Vacuum Sensor Kit'for fiberglass tanks(4',6',8',10') <br /> and sump interstices 330020-485 3 Vacuum Sensor Kt'for no tank <br /> • For monitoring double-walled steel tank 330020479 2 Vacuum Sensor Kit'for steel tank <br /> interstices(see back page) 330020-481,482,483,-484 2 Vacuum Sensor Kit`for fiberglass tanks(4',6',8',10') <br /> 330020480 2 Vacuum Sensor Kt'for no tank <br /> • For double-walled fiberglass tanks 330020495 1 Vacuum Sensor Kt'for no tank <br /> 857280-100 Vacuum Sensor for piping 8 sumps <br /> These kits differ in the number of vacuum 857280-200 Vacuum Sensor for steel tanks <br /> 857280-301,-302,-303,-304 Vacuum Sensor for fiberglass tanks(4',6',8',10') <br /> sensors and the configuration of associated 330020448 Mounting Kt <br /> liquid sensors. An inline kit mounted liquid 332217-001 Relief valve Assembly <br /> sensor is used for Vacuum Sensors 332250-001 Smart Sensor w/Embedded Pressure Sensor Module(7 ChanneQ" <br /> monitoring piping and sumps. An external Accessories Part Description Quan"A-1,11" Part Number <br /> liliquid sensor(to be installed in the secondary 1/4"NPT Barbed Fittings 3 330020-487 <br /> q r}' 1/4"NPT Barbed Fittings 15 330020-488 <br /> space at the bottom of the tank) is provided 1/4"NPT Barbed Fittings 25 330020-489 <br /> with one of the Vacuum Sensors in the steel Barbed Tee 1 576008-657 <br /> Vacuum Hose 25' 25' 332310-001 <br /> and fiberglass tank kits to monitor the tank. Vacuum Hose 50' 50' 332310-002 <br /> Vacuum Hose 100' 100' 332310-003 <br /> 3-way Ball Valve 1 576008-649 <br /> Schrader Valve Barbed Fitting 3 330020-496 <br /> Schrader Valve Barbed Fitting 15 330020-497 <br /> Kts include mounting bracket,6'of vacuum hose,relief valve assembly(f required)and the appropriate number of liquid sensors, <br /> 3-way ball valves, barbed fittings and hose damps so that each vacuum sensor can monitor a single tank,sump or piping interstices. <br /> "The Vacuum Sensing System requires one 7 channel Smart Sensor Interface with Embedded Pressure Module,8 channel Smart <br /> Sensor Modules Vin 329356-004)can be used for Vacuum Sensors eight and above. <br /> For more information call: 1-888.661-7942 <br /> VEEDER-ROOT <br />
The URL can be used to link to this page
Your browser does not support the video tag.