My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2908
>
2300 - Underground Storage Tank Program
>
PR0231021
>
COMPLIANCE INFO_2006-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2022 1:10:36 PM
Creation date
6/3/2020 9:44:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2007
RECORD_ID
PR0231021
PE
2361
FACILITY_ID
FA0003625
FACILITY_NAME
ARCO STATION #83560*
STREET_NUMBER
2908
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09763032
CURRENT_STATUS
01
SITE_LOCATION
2908 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231021_2908 W BENJAMIN HOLT_2006-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
306
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br /> INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br /> ®MMkn0jbgy <br /> TEST DATE: 03/27/08 8501 N MOPAC EXPRESSWAY,SUITE 400 WORK ORDER NUMBER: 2255784 <br /> AUSTIN,TEXAS 78759(512)451-6334 <br /> CLIENT: BP PRODUCTS NORTH SITE: ARCO #02133, CC 18022644 <br /> , 777 <br /> F�IK . amu <br /> Tank ID: #1MASTER 1 Tank manifolded: YES Bottom to top fill in inches: 133.0 <br /> Product: REG UNLEAD Vent manifolded: YES Bottom to grade in inches: 137.0 <br /> Capacity in gallons: 12,000 Vapor recovery manifolded: YES Fill pipe length in inches: 38.0 <br /> Diameter in inches: 95.00 Overfill protection: YES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 396 Overspill protection: YES Stage I vapor recovery: DUAL <br /> Material: DW STEEL Installed: ATG Stage II vapor recovery: BALANCE <br /> CP installed on: <br /> COMMENTS <br /> PSI at tank bottom: New/passed Failed/replaced New/passed Failed/replaced <br /> Fluid level in inches: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> UFT/OFT: Make: <br /> Fluid volume in gallons: Model: <br /> Tank water level in inches: S/N: <br /> Test time: NOT Open time in sec: <br /> Number of thermisters: TESTED Holding psi: NOT NOT <br /> Specific gravity: Resiliency cc: TESTED TESTED <br /> Water table depth in inches: est leak rate ml/m: <br /> Determined by(method): Metering psi: <br /> Leak rate in gph: Calib. leak in gph: <br /> Result: Results: <br /> COMMENTS COMMENTS <br /> ULLESTI�Itt )ead� , �I � '! <br /> Test time: <br /> Ullage volume: Material: DW FIBERG <br /> Ullage pressure: Diameter(in): 2.0 <br /> Results: Length(ft): 150.0 <br /> Test psi: 50 <br /> DATA FOR UTS-4T ONLY: Bleedback cc: 85 <br /> Time of test 1: Test time(min): 30 <br /> Temperature: NOT Start time: 13:07 NOT NOT NOT <br /> Flow rate(cfh): TESTED End time: 13:37 TESTED TESTED TESTED <br /> Time of test 2: Final gph: 0.000 <br /> Temperature: Result: PASS <br /> Flow rate(cfh): Pump type: PRESSURE <br /> Time of test 3: Pump make: RED JACKET <br /> Temperature: <br /> Flow rate(cfh): Impact Valves Operational: YES <br /> COMMENTS COMMENTS <br /> Printed 04/02/2008 19:26 KOHLMEYER <br />
The URL can be used to link to this page
Your browser does not support the video tag.