My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2908
>
2300 - Underground Storage Tank Program
>
PR0231021
>
COMPLIANCE INFO_2006-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2022 1:10:36 PM
Creation date
6/3/2020 9:44:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2007
RECORD_ID
PR0231021
PE
2361
FACILITY_ID
FA0003625
FACILITY_NAME
ARCO STATION #83560*
STREET_NUMBER
2908
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09763032
CURRENT_STATUS
01
SITE_LOCATION
2908 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231021_2908 W BENJAMIN HOLT_2006-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
306
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a <br /> Page of.l__ <br /> 8. ]FILL RISER CONTAINMENT SUMP TESTING .p. <br /> -Facility is NotEguipped With Fill Riser Containment Sums 0-- <br /> Fill <br /> _Fill Riser Containment Sumps are Present,but were Not Tested Q <br /> Test Method Developed By: Q Sump Manufacturer N Industry Standard Q Professional Engineer j <br /> ®Other(Specify) <br /> Test Me-thod Used: .Q Pressure Q Vacuum N Hydrostatic <br /> Q Other(Specify) ! <br /> Test E9uipuent Used: Wayne Perry Inc. See Attached Results Equipment Resolution:.0007" <br /> Sump# 7^/ sump* 7. Sump# Sump# <br /> SuiripDiameter: <br /> Sump Depth: <br /> 6 <br /> Sump Material: ,.a..�. <br /> Height from Tank Top to Top of <br /> Highest Piping Penetration: <br /> Height fxom Tank Top to Lowest <br /> Electrical Penetration: — <br /> Ccindition of sump prior to testing: did t � <br /> I'estedr 2"ABOVE HIGHEST 2"ABOVE HIGHEST 2"ABOVE HIGHEST 2"ABOVE HIGHEST <br /> Portion of Sump PENETRATION PENETRATION PENETRATION PENETRATION <br /> Wait time between applying water15 Minutes 15 Minutes 15 Minutes 15 Minutes <br /> and starting test:T. <br /> Start Time: G /' :0 7 j1 2 :0 7 C <br /> Initial Reading O tit cs I!2 7 . .x 9 <br /> Test End Time: 2 r 0 /; z ' <br /> Final Reading(RF): d./ p / ' e2 >/ ! /l 6a f 2,92-3 <br /> 9 <br /> Test Duration: 15 Min 15 Min 15 Min IS Min 15 Min 15 Min IS Min IS Min <br /> Change in Reading(Rp-RD: �t �r .ry vG o <br /> Pass/Fail Threshold or Criteria: -0.0020 -0.0020 -0.0020 0.0020 -0.0020 -0.0020 -0.0020 -0.0020 <br /> Is there a sensor in the sump? [d"Yes QNo ❑NA es Q No Q NA es Q No Q NA Q Yes Q No Cl NA <br /> Does sensor alarm when either - <br /> roduct or water is detected? "�� ©No Cl NA [s�es Q No Q NA 54-Yes Q No Cl NA Q Yes ®No Q NA i. <br /> r�Was <br /> s sensor removed for Testing? [EI-Yes I-]No Q NA l,'es Cl No Q NA [ ''Yes Q No Q NA Q Yes Q No Q NA. <br /> y sensor properlreplaced andfied functional y ed testing? n5pj-4Yes Q No [INA RI-Yes C]No Q NA [I'1'es ®No ❑NA Q Yes Q No Q NA <br /> i <br /> Comments—(include fnornwdon on repairs made prior to testing and recommended follow-up forfailed tests) <br /> i <br /> 1 <br /> BP#02133 <br /> 2908 W Benjamin Holt Dr <br /> Stockton,Ca <br /> 08103 SB989 <br /> s <br />
The URL can be used to link to this page
Your browser does not support the video tag.