My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2908
>
2300 - Underground Storage Tank Program
>
PR0231021
>
COMPLIANCE INFO_2011-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2022 2:32:40 PM
Creation date
6/3/2020 9:44:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2015
RECORD_ID
PR0231021
PE
2361
FACILITY_ID
FA0003625
FACILITY_NAME
ARCO STATION #83560*
STREET_NUMBER
2908
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09763032
CURRENT_STATUS
01
SITE_LOCATION
2908 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231021_2908 W BENJAMIN HOLT_2011-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
394
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sugov.org/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Faculty ARCO 2133 Facility 2908 Ben Holt Drive, Stockton Inspection May 16, 2012 <br /> Name: Address: Date: y <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=CA Health and Safe Code;CFR=Code of Federal Regulations <br /> C1=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> Vin-Pressurized(?rpng <br /> (continue,;g ^' <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1, 1984) (M1) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1,1984) (M1) <br /> Other V(olations „ <br /> ' .;- <br /> 999 Other: See attached"Continuation—Official Inspection Report'for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II, or MINOR-Notice to Comply) <br /> Routine Underground Storage Tank inspection. Spill container testing done on 1-27-12 and Monitoring <br /> System Certification testing done on 1-27-12 and 2-24-12 will be used to satisfy the annual testing <br /> requirements. <br /> 106, 107, 202. The monitoring plan and map on site is not current and approved by the Environmental <br /> Health Department (EHD). The monitoring plan and map do not include the new vapor condensate trap <br /> high level liquid sensor or the annular space liquid sensor. List all liquid sensors with model number and <br /> location in the comments section of the monitoring plan or on the site map. Complete and submit a copy <br /> of the monitoring plan and map for approval to the EHD by June 17, 2012. An approved copy will be <br /> returned for your records. <br /> 108. Secondary containment testing for the old vapor condensate trap sump was scheduled to be <br /> performed on August 5, 2011 by Tank-tek and a test report has not been submitted to the EHD. This <br /> testing was part of the required triennial testing for the facility. A copy of the test report must be <br /> submitted within 30 days of the test. By June 17, 2012, submit a copy of the test report to the EHD or <br /> explain why the testing was not done. <br /> 204. The designated operator failed to check and note the correct test date for the spill container test on <br /> the May 10, 2012 designated operator monthly inspection report. The report indicates that the spill <br /> containers were tested on February 24, 2012. The spill containers were tested on January 27, 2012 and <br /> were not tested on February 24, 2012. During the monthly inspection, the designated operator shall <br /> check that all required testing and maintenance for the UST system have been completed and document <br /> the dates they were done. Ensure that designated operators performing monthly inspections at this <br /> facility are including all of the required information on the reports. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inspect 71 Received By: Title: <br /> Rev 09/01/11 <br /> EHD -02 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.