COMPLIANCE INFO_2011-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2908
>
2300 - Underground Storage Tank Program
>
PR0231021
>
COMPLIANCE INFO_2011-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2022 2:32:40 PM
Creation date
6/3/2020 9:44:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2015
RECORD_ID
PR0231021
PE
2361
FACILITY_ID
FA0003625
FACILITY_NAME
ARCO STATION #83560*
STREET_NUMBER
2908
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09763032
CURRENT_STATUS
01
SITE_LOCATION
2908 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231021_2908 W BENJAMIN HOLT_2011-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
394
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
bp Emergency Shut-Off (ESO) Testing Results & Checklist <br /> it i <br /> Facility Information Contractor Information Test Results <br /> Site# 2133 Co.Name: FASTECH Date: 02/24/12 <br /> Addr. 12908 Benjamin Holt Dr. Phone. 714-523-0194 <br /> Ci /St:IStockton CA Lead Tech: Isaac Anderson Alltech Petro Inc. X PASS <br /> eMaint.W.O.# Name: or <br /> Pass ort#: FAIL(Next Day Repair Required) <br /> Signature: <br /> The objective of this test is to provide assurance that when the ESO switch is activl6fd,al.44ueling system circuits(turbines,and dispensers)are de-energized,and <br /> remain de-energized until they are reset manually. The test procedures and guidelines shall be in accordance with the ESO Testing Process. <br /> # The following information is to be completed. X To SelectYes No N/A <br /> SITE DATA <br /> 1 Number of ESO switches: 1 <br /> 2 Type of Switch Push Pull Monentary X Plain IighUToggle Other: <br /> if Momentary type,locate and identify re-set button <br /> 3 Type of Turbine Control Relay System(Electrical Distribution Center): <br /> Brown BoxI Power Solution Custom Fabricated Carolina Box 10ther <br /> 4 Type of Turbine Control Relays: I Make Red Jacket Model lCapacitor kn Control Box <br /> 5 Type of Line Leak Detection: I Imechanical ELD/CPT IPI LD X <br /> 77777-7 PERFORMANCE TEST <br /> 5 Does the ESO shutdown power tote X <br /> Does the ESO shutdown power tote X <br /> Is the 220 voltage tote turbine relay remove (either the line side or the motor side of the contacts or t e Fcojlp X <br /> 8 <br /> 9 Are the DISPENSER BREAKERS clearly i enti ielabeled? X <br /> 10 rete TURBINE BREAKERS clearly i enti ielabeled? X <br /> 11 re all the ESOs accessible and clearly i enti ielabeled? X <br /> Did the s unction correctly(de-energized from either the line si a or the motor side of the contacts or the coil)? X <br /> 12 <br /> If#12 is NO,briefly describe what was wrong: <br /> 12A <br /> How was it corrected: <br /> 12B <br /> 12C If repair or ESO functionality cannot be corrected same day(prior to leaving the site). The technician MUST notify the Site <br /> Manager of the problem,place an"Out of Service"Tag on the ESO(s),and identify an alternate mean(i.e.,locate circuit panel, <br /> iclearly identify turbine and dispenser breakers for shut-off in the event of an emergency). <br /> 12D Elite Customer Solution Center has been contacted for the repair. <br /> eMaint W.O.Ticket# <br /> 11 Site's fueling system is fully operational. X <br /> 12 All equipment secured and any access ports,lids,enclosures are closed. X <br /> 13 All safety barricades,and any debris was been removed. X <br /> COMMENTS <br /> Submit completed copy with other documentation in E-Maintenance. <br />