Laserfiche WebLink
0 <br />UL/ULC Listed Redorhread® IIA Piping stem <br />Benefits of '40 <br />Fiberglass Pipi <br />in Underground A <br />Lowest Total Cost Ownerships <br />[Material Cost + Installation Cost] - System Life <br />t Maintenance cost and replacement cost not required with RED THREAD IIA piping system. <br />Thirty Year <br />W a r r a n t y* <br />With over 40 <br />1p, Fuel Applications years proven <br />_ performance in <br />TIME TESTED the marketplace, <br />Underwriter's <br />•30 -Year Warranty - 4Laboratories, Inc. <br />and Underwriter's Laboratories <br />Canada (UL/ULC) Listed RED <br />• Installed since 1964 THREAD IIA pipe, fittings and <br />adhesive carry a 30 -year warranty. <br />• Never been removed due The product is warranted to be <br />to fuel incompatibility free from defects in material and <br />workmanship—and against internal <br />• Total immersion testing and external corrosion—when used <br />in fuels for underground transportation of <br />fuels. <br />-9 <br />t <br />2 <br />• Case History G7301 <br />LOWEST TOTAL COST <br />OF OWNERSHIP <br />• No reinstall costs due <br />to fuel incompatibility <br />• Homogenous system: no <br />liner, no bladder <br />• Leak Prevention — Sump <br />entry/termination fittings provide <br />positive seal at the sump to help <br />prevent leaking of underground <br />fuel in or out of the sump. This <br />fitting also helps provide Class <br />I (leak prevention) protection <br />which complies with California's <br />requirement for continuous <br />interstitial monitoring of the piping <br />system's secondary containment. <br />• Outstanding Corrosion <br />Resistance — RED THREAD IIA <br />piping systems resist internal and <br />external corrosion from hazardous <br />soils, fuels and other corrosive <br />fluids. <br />• Quality Assurance — FGS <br />Smith Fibercast quality assurance <br />procedures meet or exceed the <br />test requirements of UL/ULC. <br />• Permeability — RED THREAD <br />IIA permeability resistance <br />greatly exceeds UL allowable <br />permeability. <br />2004 UL 971: <br />Primary - 1 gm/m2/day <br />(0.053 gal/100 ft. of 2" pipe, <br />30 days) <br />Secondary - 4 gm/m2/day <br />(0.213 gal/100 ft. of 2" pipe, <br />30 days) <br />1995 UL 971: <br />Primary - 4 gm/m2/day <br />(0.213 gal/100 ft. of 2" pipe, <br />30 days) <br />Secondary - 24 gm/m2/day <br />(1.278 gal/100 ft. of 2" pipe, <br />30 days) <br />• txcepcionai riow.,. <br />A TRUE PIPE IN A PIPE Characteristics - Two-inch <br />RED THREAD IIA pipe has the , <br />• Interstitial space largest I.D. (2.235") in the fueling <br />communication industry—allowing you to sell twice <br />the fuel per foot than any 11/2" � <br />• Leak prevention, not flexible product on the market. <br />leak detection Three-inch RED THREAD IIA Old vs New- Pipe in the foreground was <br />fiberglass pipe has a nominal 3.36" installed in 1973 and removed 27 years <br />• INSTALL IT, BURY IT, I.D.; four -inch pipe has a 4.36" I.D. later when the station closed. <br />FORGET IT! <br />" *Please review FGS Smith Fibercast's written warranty to determine the terms and conditions. <br />