My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2908
>
2300 - Underground Storage Tank Program
>
PR0231021
>
COMPLIANCE INFO_2011-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2022 2:32:40 PM
Creation date
6/3/2020 9:44:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2015
RECORD_ID
PR0231021
PE
2361
FACILITY_ID
FA0003625
FACILITY_NAME
ARCO STATION #83560*
STREET_NUMBER
2908
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09763032
CURRENT_STATUS
01
SITE_LOCATION
2908 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231021_2908 W BENJAMIN HOLT_2011-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
394
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CALIFORNIA CODE OF REGULATIONS TITLE 23 DIVISION 3 CHAPTER 16 ARTICLES 1-11 <br />(A) The below -grade piping operates at less than atmospheric pressure <br />(suction piping); <br />(B) The below -grade piping is sloped so that the contents of the pipe will <br />drain back into the storage tank if the suction is released (gravity -flow <br />piping); <br />(C) No valves or pumps are installed below grade in the suction line. Only <br />one check valve is located directly below and as close as practical to the <br />suction pump; <br />(D) An inspection method is provided which readily demonstrates <br />compliance with subdivisions (A) through (C) above. <br />(b) All corrodible underground piping, if in direct contact with backfill material, shall be <br />protected against corrosion. Piping constructed of fiberglass -reinforced plastic, steel with <br />cathodic protection, or steel isolated from direct contact with backfill, fulfills this corrosion <br />protection requirement. Cathodic protection shall meet the requirements of section <br />2635(a)(2). <br />(c) Underground primary piping shall meet all of the following requirements: <br />(1) Primary piping in contact with hazardous substances under normal operating <br />conditions shall be installed inside a secondary containment system which <br />may be a secondary pipe, vault, or a lined trench. All secondary containment <br />systems shall be sloped so that all releases will flow to a collection sump <br />located at the low point of the underground piping. <br />(2) Primary piping and secondary containment systems shall be installed in <br />accordance with an industry code of practice developed in accordance with <br />voluntary consensus standards. The owner or operator shall certify that the <br />piping was installed in accordance with the above requirements of section <br />2635(d). The certification shall be made on the "Underground Storage Tank <br />Certification of Installation/Modification" form in Title 27, Division 3, <br />Subdivision 1, Chapter 6. <br />(d) Lined trench systems used as part of a secondary containment system shall be designed <br />and constructed according to a code of practice or engineering standard approved by a <br />state registered professional engineer. The following requirements shall also apply: <br />(1) All trench materials shall be compatible with the substance stored and <br />evaluated by an independent testing organization for their compatibility or <br />adequacy of the trench design, construction, and application. <br />31 <br />
The URL can be used to link to this page
Your browser does not support the video tag.