My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2908
>
2300 - Underground Storage Tank Program
>
PR0231021
>
COMPLIANCE INFO_2011-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2022 2:32:40 PM
Creation date
6/3/2020 9:44:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2015
RECORD_ID
PR0231021
PE
2361
FACILITY_ID
FA0003625
FACILITY_NAME
ARCO STATION #83560*
STREET_NUMBER
2908
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09763032
CURRENT_STATUS
01
SITE_LOCATION
2908 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231021_2908 W BENJAMIN HOLT_2011-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
394
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
°MONIARING SYSTEM CER 1 IF ATI®N <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each <br />monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. <br />The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name <br />Arco BP 2133 <br />Site Address: 2908 Beniamin Holt <br />Bldg. No.: <br />City: Stockton Zip: 95207 <br />Facility Contact Person: Not reported Contact Phone No.: (209) 478-5552 <br />Make/Model of Monitoring System: Veeder Root TLS 350 Date of Testing/Servicing: 4/5/2011 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate saecitic equipment inspected/serviced: <br />Tank ID: 87 main <br />Tank ID: 87 aux <br />N In -Tank Gauging Probe. <br />Model: mag probe <br />® In -Tank Gauging Probe. <br />Model: mag probe <br />N Annular Space or Vault Sensor. <br />Model: 420 <br />® Annular Space or Vault Sensor. <br />Model: 420 <br />N Piping Sump / Trench Sensor(s). <br />Model: 323 <br />® Piping Sump / Trench Sensor(s). <br />Model: 323 <br />N Fill Sump Sensor(s). <br />Model: 323 <br />® Fill Sump Sensor(s). <br />Model: 323 <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />N Electronic Line Leak Detector. <br />Model: plld 157879 <br />❑ Electronic Line Leak Detector. <br />Model: <br />N Tank Overfill / High -Level Sensor. <br />Model: probe <br />N Tank Overfill / High -Level Sensor. <br />Model: probe <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />N Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: 91 <br />Tank ID: <br />N In -Tank Gauging Probe. <br />Model: mag probe <br />❑ In -Tank Gauging Probe. <br />Model: <br />N Annular Space or Vault Sensor. <br />Model: 420 <br />❑ Annular Space or Vault Sensor. <br />Model: <br />N Piping Sump / Trench Sensor(s). <br />Model: 323 <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />N Fill Sump Sensor(s). <br />Model: 323 <br />❑ Fill Sump Sensor(s). <br />Model: <br />N Mechanical Line Leak Detector. <br />Model: vmi-Id2000 (not tested) <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />N Tank Overfill / High -Level Sensor. <br />Model: probe <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ID: 1/2 <br />Dispenser ID: 3/4 <br />N Dispenser Containment Sensor(s). <br />Model: 323 <br />N Dispenser Containment Sensor(s). <br />Model: 323 <br />N Shear Valve(s).opw-2 <br />N Shear Valve(s). opw-2 <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser 1D: 5/6 <br />Dispenser ID: 7/8 <br />N Dispenser Containment Sensor(s). <br />Model: 323 <br />N Dispenser Containment Sensor(s). <br />Model: 323 <br />N Shear Valve(s).opw-2 <br />N Shear Valve(s).opw-2 <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: transition sump <br />Dispenser ID: vapor pot <br />N Dispenser Containment Sensor(s). <br />Model: 323 <br />N Dispenser Containment Sensor(s). <br />Model: 323 <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br />correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also <br />attached a copy of the report; (check all that apply): ® System set-up ® Alarm history report <br />Technician Name (print): Omar Ruiz <br />Certification No.: B35686 <br />Signature: <br />License. No.: 794519-A HAZ C21 <br />Testing Company Name: Fueling & Service Tech., Inc. (FASTECH) Phone No.: (714) 523-0194 <br />Site Address: 7050 Village Drive, Suite D, Buena Park, CA 90621 Date of Testing/Servicing: 4/5/2011 <br />Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.