My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2908
>
2300 - Underground Storage Tank Program
>
PR0231021
>
COMPLIANCE INFO_2011-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2022 2:32:40 PM
Creation date
6/3/2020 9:44:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2015
RECORD_ID
PR0231021
PE
2361
FACILITY_ID
FA0003625
FACILITY_NAME
ARCO STATION #83560*
STREET_NUMBER
2908
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09763032
CURRENT_STATUS
01
SITE_LOCATION
2908 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231021_2908 W BENJAMIN HOLT_2011-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
394
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility ARCO Facility 2908 Ben Holt Drive, Stockton Inspection <br /> Name: Address: Date: Jan 15, 2014 <br /> VIOLATIONS <br /> # C1 C2 I M I Code Section HSC=CA Health and Safety Code;CFR=Code of Federal ReguWions <br /> C1=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> Non-Pressurized Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1,1984) (M7) <br /> 703 1 1 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1,1984) (M1) <br /> Other Violations <br /> 999 Other: See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS 11,or MINOR-Notice to Comply) <br /> Routine and Monitoring System Certification UST inspection <br /> 205. The November 2013 designated operator monthly inspection report was not found on site. <br /> Designated operator monthly inspection reports for the previous twelve months shall be retained on site. <br /> Locate and ensure that copies of the previous twelve months of designated operator monthly inspection <br /> reports are maintained on site. Submit copies to the San Joaquin County Environmental Health <br /> Department (EHD) by February 15, 2014. <br /> 305. The dispenser 1/2 and 87 middle tank fill sump liquid sensors failed to activate an audible and <br /> visual alarm when tested to ensure continuous monitoring of the tank system. All monitoring equipment <br /> shall be maintained to activate an audible and visual alarm or stop the flow of product at the dispenser <br /> when it detects a leak. The sensors were replaced and retested during the inspection. A "UST Retrofit <br /> Verification with Inspector Already Onsite" form has been completed and provided to the operator and <br /> contractor. Violation resolved. <br /> 311. The 91 octane line leak detector failed to detect a leak when tested. All line leak detectors shall <br /> be capable of detecting a 3-gallon per hour leak at 10 psi. The service technician adjusted the leak <br /> detector, retested it, and it passed. Violation resolved. <br /> Notes <br /> 1. Complete and submit a copy of the Return to Compliance Certification form with a statement of how <br /> each violation was corrected, including supporting documentation, by February 15, 2014. <br /> ALL END STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> InspecgX: Received By: Title: <br /> i <br /> 1 <br /> EH Rev 04/ 12 Page 3 UST INSPECTION REPORT <br /> i <br />
The URL can be used to link to this page