Laserfiche WebLink
INDIVIDU ANK/LINE/LEAK DETECTOR T REPORT NDE <br />NDE ENVIRONMENTAL CORPORATIONN AF <br />TEST DATE: November 10, 1994 WORK ORDER NUMBER: 963168 <br />CLIENT: TOSCO NORTMqEST COMPANY SITE: B.P. 1-1193 <br />Tank ID: <br />2 <br />Bottom to top fill in inches: <br />146.0 <br />Product: <br />REG UNLEAD <br />Bottom to grade fill in inches: <br />153.0 <br />Capacity in gallons: <br />10,000 <br />Fill pipe length in inches: <br />55.0 <br />Diameter in inches: <br />91.00 <br />Fill pipe diameter in inches: <br />4.0 <br />Length in inches: <br />360 <br />Stage I vapor recovery: <br />COAX <br />Material: <br />DW FIBERG <br />Stage 11 vapor recovery: <br />BALANCE <br />Tank: <br />No <br />5o <br />vol change cc: <br />Manifolded Vent: <br />No <br />0.008 <br />RESULT: <br />Test method: <br />vPLT <br />Psi at tank bottom: <br />1.70 <br />Fluid level in inches: <br />63.25 <br />UFT/OFT <br />UFT <br />Fluid volume in gallons: <br />7,419 <br />Water level in inches: <br />0.00 <br />Test time: <br />12:15-15:55 <br />Number of thermisters: <br />5 <br />Specific gravity: <br />0.743 <br />Water table depth in inches: <br />90.00 <br />Determined by (method): <br />MONTR WELL <br />Leak rate in gph: <br />0.005 <br />RESULT. <br />PASS <br />New/passed Failed/replaced <br />detector detector <br />Test method: FTA <br />Make: RED JAcAET <br />Model: X. L. D. <br />S/N: 310931012 <br />Open time in sec: 3.00 <br />Holding psi: 10 <br />Resiliency cc: 270 <br />;t leak rate ml/min: 189.0 <br />Metering psi: 10 <br />Calib. leak in gph: 3.00 <br />RESULT PASS <br />C EATS EfY <br />Test method: 17TS-4T system <br />Test time: 16:20-17:05 <br />Ullage volume: 2,581 <br />Ullage pressure: 2.30 <br />RESULT: PASS <br />DATA FOR UTS-4T ONLY: <br />Time of test 1: <br />Temperature: <br />Flow rate (cfh): <br />Time of test 2: <br />Temperature: <br />Flow rate (cfh): <br />Time of test 3: <br />Temperature: <br />Flow rate (cfh): <br />16:35-16:45 <br />74.10 <br />0.200-0.200 <br />16:45-16:55 <br />74.20 <br />0.200-0.200 <br />16:55-17:05 <br />74.20 <br />0.200-0.200 <br />CQM►ti1IANT�a '. <br />Material: STEEL <br />Diameter (in): <br />2.0 <br />Length (ft): <br />60.0 <br />Test psi: <br />5p <br />Bleedback cc: <br />40 <br />Test time (min): <br />30 <br />Test 1: start time: <br />10:15 <br />finish psi: <br />48 <br />vol change cc: <br />11 <br />Test 2: start time: <br />10:25 <br />finish psi: <br />49 <br />vol change cc: <br />5 <br />Test 3: start time: <br />10:35 <br />finish psi: <br />5o <br />vol change cc: <br />0 <br />Final gph: <br />0.008 <br />RESULT: <br />PASS <br />Test type: PTA -88 <br />Pump type: PREssmm Pump make: <br />Ql� ,W <br />