Laserfiche WebLink
Standard Models • <br />is <br />Tank I.D.* <br />Magnetostrictive Probe for Alternative <br />Fuels with Water Detection Form No.** <br />Magnetostrictive Probe for Alternative <br />Fuels without Water Detection Form No. ** <br />P(FA) <br />0.1 GPH Leak <br />Detection <br />0.2 GPH Leak <br />Detection <br />0.1 GPH Leak <br />Detection <br />0.2 GPH Leak <br />Detection <br />4' <br />847391-101 <br />847391-201 <br />847391-401 <br />847391-501 <br />5' <br />847391-102 <br />847391-202 <br />847391-402 <br />847391-502 <br />5'4" <br />847391-103 <br />847391-203 <br />847391-403 <br />847391-503 <br />6' <br />847391-104 <br />847391-204 <br />847391-404 <br />847391-504 <br />7' <br />847391-105 <br />847391-205 <br />847391-405 <br />847391-505 <br />7'6" <br />847391-106 <br />847391-206 <br />847391-406 <br />847391-506 <br />8' <br />847391-107 <br />847391-207 <br />847391-407 <br />847391-507 <br />9' <br />847391-108 <br />847391-208 <br />847391-408 <br />847391-508 <br />10' <br />847391-109 <br />847391-209 <br />847391-409 <br />847391-509 <br />10'6" <br />847391-110 <br />847391-210 <br />847391-410 <br />847391-510 <br />11' <br />847391-111 <br />847391-211 <br />847391-411 <br />847391-511 <br />12' <br />847391-112 <br />847391-212 <br />847391-412 <br />847391-512 <br />2.OM <br />847391-113 <br />847391-213 <br />847391-413 <br />847391-513 <br />2.5M <br />847391-114 <br />847391-214 <br />847391-414 <br />847391-514 <br />2.667M <br />847391-116 <br />847391-216 <br />847391-416 <br />847391-516 <br />3.OM <br />847391-115 <br />847391-215 <br />847391-415 <br />847391-515 <br />" Tank I.D. equals the 'A" (Probe Length) dimension on the drawing to right of the chart. Probe length (A) must <br />equal Tank I.D. <br />*" Float kits for the specific fuel application must be ordered separately. Kits are available for 4" and 2" floats. <br />Water Float is not recommended for blends with greater than 20% alcohol. <br />Leak Test Performance — with 4" Floats (Third -Party Certified) <br />PROBE <br />TEST TYPE <br />P(D) <br />P(FA) <br />TEST TIME <br />0.1 GPH Mag Probe <br />0.1 GPH <br />99% <br />1% <br />3 Hours <br />0.1 GPH Mag Probe <br />0.2 GPH <br />99% <br /><.l% <br />2 Hours <br />0.1 GPH Mag Probe w/CSLD <br />0.2 GPH <br />99% <br /><.l% <br />Continuous <br />0.2 GPH Mag 2 <br />0.2 GPH <br />99% <br /><.l% <br />2 Hours <br />Magnetostrictive Probe Console Compatibilty <br />14.5" <br />PROBE TLS -350R* TLS -350* TLS -300 TLS -300i TLS -300C TLS -250 TLS -250i <br />MAG 1 <br />MAG 2 <br />* A Four -Input Probe Interface Module is required for use of magnetostrictive probes with the TLS -350R or TLS -350 system. <br />tTLS-350R and TLS -350 systems equipped with the CSLD Software Enhancement are not compatible with 0.2 GPH Mag 2 probes. CSLD <br />requires 0.1 GPH Mag 1 probes. <br />F <br />VEEDER-ROOT <br />Environmental Products <br />The Leader in Tank Monitoring Technology <br />125 Powder Forest Drive, Post Office Box 2003, Simsbury, CT 06070-2003 TEL: (203) 651-2700, FAX: (203) 651-2719 TECH SUPPORT: (203) 651-2753 <br />BRAZIL: Sao Paulo • CANADA: Mississauga, Ontario • ENGLAND: Richmond Surrey • FRANCE: Rungis Cedex • GERMANY: Neuhausen/Filder <br />printed <br />12960 AR9 us.a 94 <br />• <br />is <br />