Laserfiche WebLink
OHILLSIDE INSTALLATI CAUTION: DO NTRIKE THE TANK <br /> Tanks may be installed on modera sloping terrain WITH STEEL <br /> � <br /> provided the slope does not exceed 10 degrees. The After backfill is brought to top of tank,it is recommended <br /> downhill side must consist of native soil. Fill dirt is not that water or product be added as ballast until piping <br /> permitted on this side to alter the grade of the slope. and final backfilling to grade is accomplished.When fill- <br /> The top of the tank must be below the surface of the ing with ballast or product, make sure the tank is ade- <br /> downhill side, and must be covered by material with quately vented. <br /> depths as stated in item 4. CAUTION—Do not ballast tank with water or product <br /> until backfill is even with top of tank(except as noted in <br /> wet hole procedure). <br /> The same material as specified in Item 3 must be used <br /> to completely fill excavation. The backfill must be free <br /> —III( 100 of debris.Any blocks or bricks used as support material <br /> — during piping must be removed prior to completion of <br /> backfilling. Safety measures, such as placing barri- <br /> cades until installation is complete, should be used <br /> III— III III_ around the excavation site. <br /> II II I = NOTE:If there is any reason to believe that water might enter the hole <br /> II IIII II ___ after installation,or if hole is in clay soil with poor drainage,anchoring <br /> is required. <br /> 12 O ET HOLE INSTALLATION <br /> II III—III — I = 1 llll 1 - 1 <br /> Pump the water from the hole to maintain minimum wa- <br /> - �1= ter level.Add a minimum of 12 inches(30 cm)of backfill <br /> 7omaterial to the hole, and level the bed to assure tom- <br /> DRY HOLE INSTALLATION plete bottom support for the tank. Position the tank in <br /> The bed must be smooth and level, and must contain a the hole.The 24 inch(60 cm)spacing between tank and <br /> minimum of 12 inches (30cm) of smooth and level pea side wall must be maintained as a minimum in a wet <br /> gravel or stone crushings. (See (2)) ,Place the tank or hole installation. <br /> tanks on the bed carefully. Do not install Xerxes Partially fill the tank with water until it settles firmly on <br /> Century-Cast Tanks directly on a concrete slab,or grout the prepared bed. Ballast level in a tank must never <br /> tanks in wet concrete. Also, do not install these tanks exceed water level in hole during installation. Use only <br /> on timbers,beams,cradles or directly on the hole bottom. enough water to ballast the tank until backfill material is <br /> Leveling even with the top of the tank. <br /> After leveling tanks, <br /> After the tank is bedded, and prior to backfilling, it must the anchoring proce- <br /> be leveled. For longitudinal leveling,place the level across dures in Item 9 must <br /> the tank ribs at the top surface. Lateral leveling is ac- be followed. <br /> complished by placing the level across the top of the Backfill must be added <br /> tank outlet or manway. evenly after anchor- <br /> Backfilling ing, and remaining dry <br /> Backfill uniform) with the same material used for bed- hole backfilling pro- — <br /> Y cedures should be -- <br /> ding. In freezing conditions make sure the material is followed as stated in - — _ <br /> dry and free of ice and snow.First,place a 12 inch(30cm) Item 7. �2" <br /> lift of backfill evenly around the tank. Work the material <br /> completely beneath the tank body and endcaps by hand <br /> in order to provide full support.A board or tamping bar <br /> should be used to NOTE:Cover depth must meet minimum depth specified in Item 4 of <br /> force the material in these installation instructions. <br /> place.After the first WRONG NOTE:It is recommended the tank be ballasted with water or product <br /> 18-24 inches (45- •°°� once backfill is even with the top of the tank. <br /> ti <br /> 60cm) of backfill is <br /> in place, use the <br /> tamping bar to work = _ _ _ IN <br /> the backfill into the <br /> voids under the <br /> edges of the tank RIGHT <br /> and ribs and around �8$ <br /> the endcaps. Re- <br /> mainder of backfill <br /> can now be done111 MIMI <br /> without further hand <br /> work. <br />