My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998-2003
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3202
>
2300 - Underground Storage Tank Program
>
PR0231129
>
COMPLIANCE INFO_1998-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2021 4:16:13 PM
Creation date
6/3/2020 9:44:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2003
RECORD_ID
PR0231129
PE
2361
FACILITY_ID
FA0001817
FACILITY_NAME
7-ELEVEN INC #35355
STREET_NUMBER
3202
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95209
CURRENT_STATUS
01
SITE_LOCATION
3202 W Hammer Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\H\HAMMER\3202\PR0231129\DIESEL TANK CONVERSION PLAN 2003.PDF
QuestysFileName
DIESEL TANK CONVERSION PLAN 2003
QuestysRecordDate
11/15/2011 8:00:00 AM
QuestysRecordID
162827
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
319
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br /> TEST DATE:10/27/03 8900 SHOAL CREEK,BUILDING 200 WORK ORDER NUMBER2228889 <br /> CLIENT:CONOCO PHILLIPS AUSTIN,TEXAS 78757(512)451-6334 SITE:CONOCO 2705448 <br /> Tank ID: #2 2 Tank manifolded: NO Bottom to top fill in inches: 175.0 <br /> Product: PLUS Vent manifolded: YES Bottom to grade in inches: 182.0 <br /> Capacity in gallons: 10,369 Vapor recovery manifolded: YES Fill pipe length in inches: 57.0 <br /> Diameter in inches: 118.00 Overfill protection: YES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 221 Overspill protection: YES Stage I vapor recovery: DUAL <br /> Material: DW FIBERG Installed: ATG Stage II vapor recovery: ASSIST <br /> CP installed on: <br /> COMMENTS <br /> Start(in) End(in) <br /> Dipped Water Level: 0.00 0.00 New/passed Failed/replaced New/passed Failed/replaced <br /> Dipped Product Level: 68.00 68.00 L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> Probe Water Level: 0.003 0.003 Make: <br /> Ingress Detected: Water N Bubble N UllageN Model: <br /> Test time: 09:54-11:11 S/N. <br /> Inclinometer reading: 0.00 Open time in sec: <br /> : <br /> VacuTect Test Type: Multiple tanks Resiliency Holding psi: <br /> NOT NOT <br /> VacuTect Probe Entry Point: Fill Test leak rate ml/m: TESTED TESTED <br /> Pressure Set Point: -0.66 Metering psi: <br /> Tank water level in inches: 0.00 Calib.leak in gph: <br /> Water table depth in inches: 180.00 Results: <br /> Determined by(method): MONTR WELL <br /> Result: PASS <br /> COMMENTS <br /> COMMENTS <br /> DOUBLE WALL, DRY ANNULAR, FIEBERGLASS TANK. <br /> Material: DW FIBERG <br /> Diameter(in): 2.0 <br /> Length(ft): 100.0 <br /> Test psi: <br /> Bleedback cc: <br /> Test time(min): NOT NOT NOT NOT <br /> Start time: TESTED TESTED TESTED TESTED <br /> End time: <br /> Final gph: <br /> Result: <br /> Pump type: PRESSURE <br /> Pump make: FE PETRO <br /> COMMENTS Impact Valves Operational: UNKNOWN <br /> Printed 11/03/2003 16:22 <br />