My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004-2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3202
>
2300 - Underground Storage Tank Program
>
PR0231129
>
COMPLIANCE INFO_2004-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/18/2023 2:36:32 PM
Creation date
6/3/2020 9:45:02 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2007
RECORD_ID
PR0231129
PE
2361
FACILITY_ID
FA0001817
FACILITY_NAME
7-ELEVEN INC #35355
STREET_NUMBER
3202
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95209
CURRENT_STATUS
01
SITE_LOCATION
3202 W Hammer Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231129_3202 W HAMMER_2004-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
275
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
10 <br /> SAN JOAQUIN COUNTY <br /> - w r •,y� <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> _. 304 East Weber Avenue, 3rd Floor, Stockton, CA 95202-2708 <br /> Telephone:(209)468-3420 Fax:(209)464-0138 Web:www.sjgov.org/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Facility name: Designated Operator: Inspection Date: <br /> s v1(- —0 <br /> Facility address: UST# <br /> Lvwe- Product I" p� �/ / <br /> Facility Contact: Title: Phone: <br /> OLa _ O'6 . <br /> Monitoring Panel: Piping system: Overfill prevention: <br /> -f<–S 35 1 71'ressurized ❑Suction ❑Gravity Mechanical ❑Audible/visual <br /> Inspection type: Violations: <br /> 19 Routine 9'Monitoring Certification ❑Installation ❑Other: ❑M1-RDetect ❑M2-RPrev VM-3 Both <br /> VIOLATIONS) HSC=California Health&Safety Code;CCR=California Code of Regulations V R <br /> # Code Section V <br /> V=Violation;RV=Re eat Violation <br /> I HSC 25284 Permit tooperate <br /> 2 CCR 2637 Secondary containment test performed <br /> 3 CCR 2711 (b)&(c) Current Unified Program Consolidated Forms on file with EHD(Facility and tank form) <br /> 4 HSC 25292.2 Certification of financial responsibility and CFO letter <br /> 5 CCR 2632(c)(2)(D) Monitoring&response plan is current and filed with the local agency <br /> 6 CCR 2712 i Monitoring&response plan is onsite <br /> 7 CCR 2712(b) Maintenance&monitoring records (MI) <br /> 8 CCR 2643 d) Daily monitoring of suction piping(pre-January, 1, 1984) <br /> 9 HSC 25292.1 UST system isoperated to prevent unauthorized release <br /> 10 CCR 2632(c)(2) UST monitoring system is present M1 <br /> 11 CCR 2630(d) UST system monitoring equipment is properly located to detect a leak (Mi) <br /> 12 HSC 25291 UST system monitoring equipment isoperational M2 <br /> 13 CCR 2636(f)(1) Continuous monitoring system for underground piping&UDC is present (Mi) <br /> 14 CCR 2631 a Primary containment is product tight <br /> 15 HSC 25291 (a)(2) Secondary containment for UST is tight <br /> 16 CCR 2636(c)(1) All releases in secondary pipingflow to a collection sum <br /> 17 HSC 25291 ( Line leak detector(s)are installed MI <br /> 18 CCR 2635(b)(1) Spill container M2 <br /> 19 CCR 2635(b)(2) Overfill prevention system (MZ) <br /> 20 CCR 2636(a) Conventional suction piping shall have continuous monitoring&2°containment <br /> 21 HSC 25291 (e) Water in 2°containment analyzed&properly disposed of <br /> 22 CCR 2650 Recording/reporting of unauthorized releases (Mi) <br /> 23 CCR 2715 Designated Operator: (a)Statement from UST owner (c-e) onthl ins ection (f) to ee training t/ <br /> 24 CCR 2638(a) Annual monitoring certification <br /> 25 CCR 2638(a) Annual line leak detector test (Ml) <br /> 26 1 HSC 25284.2 Annuals ill containment testing <br /> 27 CCR 2636(f)(4) Annual line tightness test (Ml) <br /> 28 CCR 2661 Repair for tank/piping has had tightness test M2 <br /> 29 CCR 2643(e) Biennial tightness test of gravity piping( re-January 1, 1984) <br /> 30 CCR 2643 d Triennial line test for conventional suction piping(pre-January1, 1984 Ml <br /> 31 HSC 25292.5 Double walls stem located within 1000'of public well-ELD <br /> 32 1 CCR 2661 Permit to repair UST system <br /> 33 HSC 25286(a) Permit to alter monitoring system <br /> 34 HSC 25298 b) Permit to temporarily close UST system <br /> 35 HSC 25298(c) Permit to close UST system <br /> 36 HSC 25299(a)(9) Disabling leak detection devices <br /> 37 HSC 25298(a) Illegal abandonment of UST system <br /> 38 Other: <br /> EHD INSPECTOR: PHONE: UIC <br /> Septic system: <br /> ❑Serves>_20 ople/day <br /> RE IVSD BY TITLE: ❑Recei other than sanitary waste <br /> — �� I^ Other ' osal methods: <br /> e-r wells/French Drains <br /> EHD SOT 1 4 -3 <br /> 1/3/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.