Laserfiche WebLink
MONIT ING SYSTEM CERTI CATRtCFEIVED <br /> CERTIFICATION/TEST DATE: Au ust 15, 2014 <br /> Al. FACILITY A2. OWNER "UU 4U14 <br /> Name 7-Eleven Market#2369/Store#35355 Name 7-Eleven,Inc ���� <br /> Address 3202 W.Hammer Lane,Stockton,CA 95209 Address P.O.Box 711,DaI1bA,`tf 1%%NMENTAL HEALT <br /> Phone# 209-957-2900 Phone# 805-523-2949 DEPARTMENT <br /> contact Stephen Boyd I I Contact Stephen Boyd <br /> D. RESULTS OF TESTING/SERVICING <br /> Make/Model of Monitoring System: Veeder-Root TLS-350 <br /> Software Version Installed: 332.00 <br /> Complete the following checklist: <br /> ■ Yes ❑ No* Is the audible alarm operational? <br /> ■ Yes ❑ No* Is the visual alarm operational? <br /> ■ Yes ❑ No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> ■ Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br /> will not interfere with their proper operation? <br /> ❑ Yes ❑ No* If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modems) <br /> ■ N/A operational? <br /> ❑ Yes ❑ No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment <br /> ■ N/A monitoring system detects a leak,fails to operate,or is electrically disconnected? If yes:which sensors initiate <br /> positive shutdown? (check all that apply) ❑ Sump/Trench sensors; ❑ Dispenser Containment Sensors. <br /> ❑ Yes ■ No* Did you confirm positive shut-down due to leaks and sensor failure/disconnection? <br /> ❑ Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no <br /> ■ N/A mechanical overfill prevention valve is installed),is the overfill warning alarm visible and audible at the tank <br /> fill point(s)and operating properly? If so,at what percent of tank capacity does the alarm trigger? % <br /> ■ Yes* ❑ No Was any monitoring equipment replaced? If yes,identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E,below. <br /> ❑ Yes* ■ No Was any liquid found inside any secondary containment systems designed as dry systems? <br /> (Check all that apply) ❑ Product; ❑ Water. If yes,describe causes in Section E,below. <br /> ■ Yes ❑ No* Was monitoring system set-up reviewed to insure proper settings? Attach set-up reports,if applicable. <br /> ■ Yes ❑ No* Is all monitoring equipment operational per manufacturer's specifications? <br /> * In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. COMMENTS <br /> This is a test of the new 87 annular sensor only. <br /> ®2014 Walton Engineering,Inc. <br /> Page 2 of 3 <br />