0 I <br />5 WRCB, January 2002 «IR C,Page 1 of 1 <br />7. UNDER -DISPENSER CONTAINMENT (UDC)' <br />Test Method Developed By: ' UDC Manufacturer rY—",, Industry Standard v_ Professional Engineer <br />r Other S eci <br />Test Method Used By: r Pressure r Vacuum r%0-0',' Hydrostatic <br />r Other (Specify) <br />Test Equipment Used: VPLT <br />Equipment Resolution: 0.00001 in. <br />UDC Manufacturer: <br />UDC # 1/2 <br />gilbarco <br />gilbarco <br />gilbarco <br />gilbarco <br />UDC Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />UDC Depth: <br />30.00 <br />30.00 <br />30.00 <br />30.00 <br />Height from UDC Bottom to Top <br />of Highest PipinE Penetration: <br />11.00 <br />11.00 <br />11.00 <br />11.00 <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />17.00 <br />13.00 <br />12.00 <br />15.00 <br />Condition of UDC prior to <br />testin : <br />good <br />good <br />good <br />good <br />Portion of UDC Tested' <br />13 <br />13 <br />13 <br />13 <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?* <br />r Yes r No r NA <br />f+ Yes f No C NA <br />r Yes f ` No r NA <br />fo Yes r No r NA <br />Turbine shutdown response time <br />03:00:00 sec <br />03:00:00 sec <br />03:00:00 sec <br />03:00:00 sec <br />Is system programmed for fail- <br />safe shutdown?* <br />C yes r No r NA <br />ro Yes r Nor NA <br />C Yes C No r NA <br />G Yes r No r NA <br />Was fail-safe verified to be <br />operational?* <br />C yes r No r NA <br />t+ Yes r No r NA <br />0 Yes t"' Nor NA <br />C Yes r Nor NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />5 min <br />5 min <br />5 min <br />5 min <br />Test Start Time: <br />12:44:00 <br />12:44:00 <br />13:05:00 <br />13:05:00 <br />Initial Reading (RI): <br />0.00000 in. H2O <br />0.00000 in. H2O <br />0.00000 in. H2O <br />0.00000 in. H2O <br />Test End Time: <br />12:59:00 <br />12:59:00 <br />13:20:00 <br />13:20:00 <br />Final Reading (RF): <br />-0.00110 in. H2O <br />-0.00100 in. H2O <br />-0.00040 in. H2O <br />0.00070 in. H2O <br />Test Duration: <br />15 min <br />15 min <br />15 min <br />15 min <br />Change in Reading (RF -RI) : <br />-0.00110 in. H2O <br />-0.00100 in. H2O <br />-0.00040 in. H2O <br />0.00070 in. H2O <br />Pass/Fail Threshold or Criteria: <br />+/-0.00200 <br />+/-0.00200 <br />+/-0.00200 <br />+/-0.00200 <br />Was sensor removed for testing? <br />G Yes f Nor NA <br />�.. <br />G Yes r, No r NA <br />Passe : <br />Co Yes r No C NA <br />Pass <br />r Yes 47 No P NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />C yes r Nor NA <br />+ Yes r Nor NA <br />is Yes r Nor NA <br />r Yes r No r NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />1 If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an asterisk (•) is "NO" or "NA", the entire UDC must <br />be tested. <br />WO: 2314294 <br />