My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1995-1999
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOWER SACRAMENTO
>
8660
>
2300 - Underground Storage Tank Program
>
PR0231161
>
COMPLIANCE INFO_1995-1999
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2020 3:54:44 PM
Creation date
6/3/2020 9:45:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1995-1999
RECORD_ID
PR0231161
PE
2361
FACILITY_ID
FA0003726
FACILITY_NAME
fast and easy mart #103
STREET_NUMBER
8660
STREET_NAME
LOWER SACRAMENTO
STREET_TYPE
RD
City
STOCKTON
Zip
95210
APN
079-170-390-000
CURRENT_STATUS
01
SITE_LOCATION
8660 LOWER SACRAMENTO RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231161_8660 LOWER SACRAMENTO_1995-1999.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
448
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�yov�cty <br /> STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br /> `i <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLO IT <br /> ONE ITEM F72 INTERIM PERMIT f74 AMENDED PERMIT F76 TEMPORARY TANK CLOSURE El TANK REMOVED I <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: P,tG Ro <br /> 1. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN G C <br /> 4 OWNER'S TANK I.D.# Z B. MANUFACTURED BY: XERX�^S <br /> C. DATE INSTALLED(MO/DAYNEAR) Z 15 q9 Ct) I D. TANK CAPACITY IN GALLONS: 110, 000 <br /> II TANK CONTENTS IF A-1 IS MARKED,COMPLETE ITEM C. <br /> A. Cg 1 MOTOR VEHICLE FUEL ❑ 4 OIL B. C. ❑ to REGULAR UNLEADED ❑ 3 DIESEL ❑ 6 AVIATION GAS <br /> ❑ 1b PREMIUM UNLEADED ❑ 4 GASAHOL ❑ 7 METHANOL <br /> F7 2 PETROLEUM ❑ 80 EMPTY t PRODUCT f171 tc MIOGRADE UNLEADED ❑ 5 JET FUEL ❑ 8 M85 <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE 1❑� 2 LEADED ❑ 99 OTHER(DESCRIBE IN ITEM 0.BELOW) <br /> 0. IF(A.1)IS NOT MARKED. ENTER NAME OF SUBSTANCE STORED C.A.S.# <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.B.AND C,AND ALL THAT APPLIES IN BOX 0 AND E <br /> A. TYPE OF }bl 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR UNER ❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAULT ❑ 89 OTHER <br /> B. TANK ❑ 1 BARE STEEL- ❑ 2 STAINLESS STEEL 3 FIBERGLASS ❑ 4 STEEL CLAD W1 FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W/FRP <br /> (Primary Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY UNING ❑ 4 PHENOLIC LINING <br /> LINING OR F7 5 GLASS LINING 29 6 UNLINED F795 UNKNOWN F799 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES_ NO— <br /> D•EXTERIOR ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION ❑ ❑ 91 NONE n 95 UNKNOWN El 99 OTHER <br /> PROTECTION 5 CATHODIC PROTECTION ,_, <br /> E.SPILL AND OVERFILL,etc. SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> DROP TUBE YES—L4— NO STRIKER PI ATE YES NO DISPENSER CONTAINMENT YES NO <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A O 2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLE PIPING A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL AQ 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U B 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION ❑1 ME..UNE LEAK ❑2 UNE TIGTNE <br /> HSS X71 3 CONTINUOUS INTERSTMAL �4 ELECTRONIC UNE IG 5 AWOMATIC PUMP 17 99 OTHER <br /> OEMCTOR TESTING id MOMTORING LEAK DETECTOR 1� SNUTOOWN U <br /> V.TANK LEAK DETECTIONGROUND1 <br /> ❑ 1 VISUAL CHECK ❑ 2 RECONCiLIAT10NORY ❑ 3 MONOITORING `4 GAUGING AUTOMATIC TANK ❑ 5 MONITORINGTER ❑6STINANNUAL MANUAL <br /> GTANK <br /> 7 MONITORING INTERSTITIAL ❑ 8 SIR ❑ 9 WEEK LY MANUAL ❑ 10 MONTHLY TANK 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PLACE) MIA <br /> 1.ESTIMATED DATE LAST USED(MO/DAYNR) I 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES ❑ NO❑ <br /> SUBSTANCE REMAINING GALLONS I INERT MATERIAL? <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT <br /> TANK e200101 S NAME LA <br /> (67 DATE / n <br /> (PRINTED 6 SIGNATURE) <br /> CAL tA <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW I <br /> COUNTY# JURISDICTION# FACILITY#37,2- TANK# 0107 <br /> STATE I.DJ m � � 3 ( b I . 151c) 1 Y1 31 M7 7 6 9y <br /> PERMIT NUMBER PERMIT APPROVED BY/OATE PERMIT EXPIRATION DATE <br /> i <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLIC IN-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. FO'-'C MUST BE COMPLETED FOR INSTALLATIONS.THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT PL jWTHIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE'0GROUND STORAGE TANK REGULATIONS <br /> FORMS (6-95) <br />
The URL can be used to link to this page
Your browser does not support the video tag.