COMPLIANCE INFO_2002-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOWER SACRAMENTO
>
8660
>
2300 - Underground Storage Tank Program
>
PR0231161
>
COMPLIANCE INFO_2002-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 2:51:09 PM
Creation date
6/3/2020 9:45:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2015
RECORD_ID
PR0231161
PE
2361
FACILITY_ID
FA0003726
FACILITY_NAME
fast and easy mart #103
STREET_NUMBER
8660
STREET_NAME
LOWER SACRAMENTO
STREET_TYPE
RD
City
STOCKTON
Zip
95210
APN
079-170-390-000
CURRENT_STATUS
01
SITE_LOCATION
8660 LOWER SACRAMENTO RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231161_8660 LOWER SACRAMENTO_2002-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
484
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page of <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed lay: !:.l Stump Manufacturer ❑Industry Standard X Professional Engi w� <br /> neer <br /> 0 Other(Specify) <br /> ............. <br /> Test Method Used: D Pressure 0 Vacuum X Hydrostatic <br /> D Other(Spee) <br /> �! � =E: <br /> ' Sum .;#3 � � . #s <br /> Lest Equipment Used Caldwell Systems Equipment Resolution .005/30 min <br /> mp <br /> y <br /> Sum # l Sump <br /> Sump Diameter: 48" 48" 48" <br /> _..._ _ <br /> Sump Depth: 45" 46" 49" <br /> .............._.... <br /> _— <br /> 1 Sump Material: Fiberglass Fiberglass Fiberglass <br /> Height from Tank Top to Top of <br /> 14" 13" 13> <br /> ' Ilighest Piping Penetration: <br /> Height from Tank Top to Lowest 16" 12" 14" <br /> t Electrical Penetration: <br /> _.__._.. <br /> Condition of sump prior to testing: Ivry Dry Dry <br /> ...... <br /> Portion of Sump Tested' 2"above Highest Piping Penetration <br /> Does turbine shut down when <br /> sump sensor detects liquid(both x Yes i:a No n NA x Yes : ;No DNA x Yes D No DNA D Yes n No NA j <br /> product and water)`. I <br /> i Turbine shutdown response time <br /> Is system programmed for fail-safe x Yes C'1 No f NA x Yes �1 No DNA x Yes DNo DNA 0 Yes 1� No DNA <br /> shutdown? _ <br /> Was fad-safe verified to be <br /> Yesx No ! NA ❑Yes x No 0 NA 0 Yes x No 0 NA 0 Yes !.]No l`!'NA <br /> 3 <br /> operational?* j <br /> Wait time between applying 1 <br /> pressure/vacuum/water and starting 5 min 5 min 5 min 5 min <br /> test. <br /> I--- <br /> Test <br /> _Test Statt Time: d 9:3010:25 10:05 <br /> Initial Reading(111): 00" 00" .00" .00" <br /> Pest End Time: 10:00 10:55 10:35 <br /> Final Reading(RF): .00 —�� .00 _00 <br /> Test Duration: 30 rni.n 30 min ! 30 min 30 ruin <br /> Change in Reading(Rr-Rj): .00 ^� .00 .00 <br /> Pass/Fail Threshold or Criteria: .005/30 min .005/30 min .005/30 min .005/30 min <br /> 'lest Result: x Pass 0 Fail x Pass D Fail x Pass 0 Fail 0 Pass ❑Nail <br /> ._. <br /> z Was sensor removed for testing? x Yes D No DNA x Yes No 7NA x Yes D No DNA - Yes F.No NA ` <br /> r--- <br /> Was sensor properly replaced and <br /> x Yes U No a NA x Yes QNo iwl NA x Yes D No DNA Yes r rNo JNA <br /> w verified funcxionai after testin���u 1 <br /> Comments—(include infvrmauon un repaira made prior to testinK, and recommended follow-rep for failed tes(s) <br /> if the entire depth of the sump is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />