Laserfiche WebLink
I.VRRVlBYn rnVIGLa - - - <br />USY SYSTEM PRiNTSET <br />INFORMATION <br />1. <br />Four complete sets of plans (To include specification sheets and/or equipment brochures if not on file). <br />Z, % <br />Plans drawn to scale in ten -erasable print. <br />3. <br />Plot plan to show location and number of tanks. <br />4. <br />Tank cross-sectional diagram included an prints submitted. <br />5. <br />Detail of tank, piping system, excavation and cover. <br />6. <br />Tank(s) and piping approved by a nationally recognized independent testing organization. [Title 23, Subehapter 16, <br />Article 3, Sec. 2631 (r) & 26351 <br />7. is <br />Verification of product compatibitity with the tank(s), piping, monitoring <br />device(s), epoxy or silicone glues, etc. [Section 2635 (b) (2)] <br />3. <br />Manufacturer's written installation instructions for tank(s), piping, monitoring devices, etc. [Section 2635 (b) (5)] <br />9. <br />Tightness Test (NFPA 30) is required an both primary (10) and secondary (20) containment systema; before covering. <br />[Section 2635 (b) (6) & (7)] <br />10. id <br />Double walled tanks rasing pressure or vacuum testing to monitor the annular space. [Section 2635 (b) (7)] <br />11, is <br />NFPA 329 "Precision Test" required upon completion of installation with tank in operating condition. Test results to <br />be submitted directly to PNS/EHD from the testing company or owner of facility. tNealth & Safety Code, Division 20, <br />Chapter 6.7, Section 25291 (g)] <br />12. TANK CON POS ITION <br />TANK # <br /># j # 2, # # # <br />CAPACITY] <br />,ono i % Ooo 15 Oo0 <br />MANUFACTURER <br />ml, o o E <br />J oco- <br />COMPOSITION <br />MODEL <br />PRODUCT <br />nnnxrrenu %rJ f"�LA <br />I.VRRVlBYn rnVIGLa - - - <br />U.L. LISTED y s Ye s <br />COMPATIBILITY WITH 100% YES Yi�'S YE'S <br />METHANOL <br />13. TANK(s) TO BE INSTALLED <br />A. Steel -clad with fiberglass reinforced plastic. <br />B. Holiday test required immediately before "setting" tank(s) (35,000 - 40,000 volts). [Section 2635 (b) (03 <br />N IA C. Fiberglass [Sections 2635 (3) and 2631 (p)] <br />(1) Striker plate dimmensions and materials. <br />(2) Striker plate under all accessible openings. <br />(3) Installation instructions require an air test and soap bubble test prior to installation. <br />NIA D. Non -clad steel tank [Section 2635 (b)] <br />(1) Cathodic protection provided for entire tank, piping and components (nuts, bolts, washers, <br />etc.). <br />(2) Approved by a corrosion engineer or N.A.C.E. technician. <br />(3) Document stating inspection method and frequency (minimmmammsemi-annual inspection requirement). <br />9 <br />