M
>
MARCH
>
2701
>
2300 - Underground Storage Tank Program
>
PR0231176
>
COMPLIANCE INFO_2007-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2023 4:06:45 PM
Creation date
6/3/2020 9:46:05 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2009
RECORD_ID
PR0231176
PE
2361
FACILITY_ID
FA0003798
FACILITY_NAME
MARCH LANE 76*
STREET_NUMBER
2701
Direction
W
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95219
APN
11619007
CURRENT_STATUS
01
SITE_LOCATION
2701 W MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231176_2701 W MARCH_2007-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
323
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAMPLING PROTOCOL FOR ROUTINE PIPING/DISPENSER REMOVAL/REPLACEMENT <br />The following represents minimum sampling criterion required for closure compliance. Soil samples collected shall be <br />representative of native soils beneath the tank's invert (tank's bottom) at a collection depth not to exceed 2 - 4 feet. if <br />contamination is documented during closure, an Unauthorized Release Notification must be completed and submitted within five (5) <br />working days pursuant to California Health & Safety Code, Section 25295. <br />nil_QPFA1CFR PIpmr. Amn CTnrWPII F .0®MPI FS <br />Tri -Regional Recommendations <br />Appendix A <br />TABLE #2 RECOMMENDED MINIMUM VERIFICATION ANALYSES <br />FOR UNDERGROUND STORAGE TANK INVESTIGATIONS <br />Notes: <br />1. EPA Method 8260B analyses must include all analytes listed in the method plus fuel oxygenates methyl -tertiary -butyl ether <br />(MTBE), diisopropyl ether (DIPS), ethyl -tertiary -butyl ether (EtBE), tertiary -amyl -methyl ether (TAME), tertiary -butanol (TBA), <br />methanol and ethanol and fuel additives 1,2-dichloroethane (1,2 -DCA) and ethylene dibromide (EDB or 1,2-dibromoethane). <br />2. If pentachlorophenol (PCP) is identified, analyze the soil and/or water sample for dioxins and furans by EPA Method 8290 - <br />and pesticides by EPA Method 8081A. <br />3. Method 601 OB may be used for all the following metals, for which individual AA methods are required: Antimony & Arsenic <br />by 7062, Cadmium by 7131A, Lead by 7421, Mercury by 7471A, Nickel by 7521, Selenium by 7742, and Thallium by 7841. <br />4. Non-proprietary, performance based analytical methods may be used with approval of Regional Board staff. <br />Revised 8/8/06 <br />3 <br />DISPENSER SAMPLES <br />1 Sample beneath each dispenser <br />PIPING SOIL SAMPLES <br />1 Sample every 20 lineal feet <br />DISPENSER & PIPING STOCKPILE SAMPLES <br />2 Samples every 50 cubic yards <br />Tri -Regional Recommendations <br />Appendix A <br />TABLE #2 RECOMMENDED MINIMUM VERIFICATION ANALYSES <br />FOR UNDERGROUND STORAGE TANK INVESTIGATIONS <br />Notes: <br />1. EPA Method 8260B analyses must include all analytes listed in the method plus fuel oxygenates methyl -tertiary -butyl ether <br />(MTBE), diisopropyl ether (DIPS), ethyl -tertiary -butyl ether (EtBE), tertiary -amyl -methyl ether (TAME), tertiary -butanol (TBA), <br />methanol and ethanol and fuel additives 1,2-dichloroethane (1,2 -DCA) and ethylene dibromide (EDB or 1,2-dibromoethane). <br />2. If pentachlorophenol (PCP) is identified, analyze the soil and/or water sample for dioxins and furans by EPA Method 8290 - <br />and pesticides by EPA Method 8081A. <br />3. Method 601 OB may be used for all the following metals, for which individual AA methods are required: Antimony & Arsenic <br />by 7062, Cadmium by 7131A, Lead by 7421, Mercury by 7471A, Nickel by 7521, Selenium by 7742, and Thallium by 7841. <br />4. Non-proprietary, performance based analytical methods may be used with approval of Regional Board staff. <br />Revised 8/8/06 <br />3 <br />