Laserfiche WebLink
Monitoring System Certification - Page 2 of 3 <br />R <br />Site Address: 2701 March Ln. Date of Testing/Servicing: 12118/13 <br />D. Results of Testing / Servicing <br />Software Version Installed. 331.00 <br />Coninlete the ffilinwina rherklict- <br />0 Yes <br />0 No* <br />Is the audible alarm <br />0 Yes <br />0 No* <br />Is the visual alarm operational? <br />IN Yes <br />0 No* <br />Were all sensors visually inspected, functionally tested, and confirmed oEerational? <br />11 Yes <br />13 No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br />not interfere with their EroEer operation? <br />13 Yes <br />0 No* <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br />IN N/A <br />operational? <br />0 Yes <br />13 No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />0 N/A <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shut -down? (Check all that apply) W Sump/Trench Sensors; 0 Dispenser Containment Sensors. <br />Did Lou confirm positive shut -down due to leaks and sensor failureldisconnection? 0 Yes 0 No <br />N Yes <br />0 No* <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />13 N/A <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger?. 90 % <br />11 Yes* <br />0 No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer name and model for all replacement parts in Section E, below. <br />m Yes* <br />o No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br />E3 Product; M Water. If yes, describe causes in Section I, below. <br />M Yes <br />0 No* <br />Was monitoring system set-up reviewed to ensure proper settings? (Attach set-yre arts I(Melicable.) <br />M Yes <br />a Na*j <br />!MiEment operational per manufacturer's specifications? <br />In Section <br />E below. describe how and when there cipfiripne-im were nr will ho oarroeforl <br />E. Comments: Removed approx 6oz of liquid from all STP Sumps. <br />Replaced TLS Battery for PM purposes. <br />Replaced Disp # 9110 (Diesel) Float Arm, Float on Disp # 112 (91) & Diesel Probe Floats - <br />Re -tested & Passed. <br />