My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
2701
>
2300 - Underground Storage Tank Program
>
PR0231176
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2023 4:14:10 PM
Creation date
6/3/2020 9:46:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231176
PE
2361
FACILITY_ID
FA0003798
FACILITY_NAME
MARCH LANE 76*
STREET_NUMBER
2701
Direction
W
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95219
APN
11619007
CURRENT_STATUS
01
SITE_LOCATION
2701 W MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231176_2701 W MARCH_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
356
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6. PIPING SUW TESTING <br />RE(;L:iVtLJ <br />JnN 0 2 2014 <br />ENVIRONMENTAL <br />HEALTH DEPARTMENT <br />Test Method Developed By: <br />[3 sump Manufacturer M Industry Standard 0 Professionat Engineer <br />0 Other (Specify) <br />Test Method Used: <br />11 Pressure <br />[3 Other (Specify) <br />0 Vacuum <br />0 Hydrostatic <br />Test Equipment Used:.Incon Sump Tester <br />STp HE <br />Sump # 87 <br />Sump Diameter. 42" <br />1 <br />STP Sump # 91 <br />42" <br />Equipment solution: 0.002" <br />STP Sump # Diesel <br />42" <br />.sump Depth: <br />7111 <br />7211 <br />72" <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Height from Tank Top to Top of <br />jEest Ming Penetration: <br />189' <br />19, <br />Height from Tank Top to Lowest <br />Electrical Penetration. - <br />16" <br />15" <br />16„ <br />Condition of sump prior to testing: <br />Good <br />Good <br />Good <br />Portion of Sump Tested' <br />2" above piping <br />27 above piping. <br />2" above piping <br />Do" turbine shut down when <br />sump sensor detects liquid (both <br />product and water)?" <br />L3 Yes 0 No 0 NA <br />[3 Yes 0 No ENA <br />0 Yes 0 No ®NA <br />Turbine shutdown response time <br />N/A <br />N/A <br />N/A <br />Is system programmed for fail-safe <br />shutdown?" <br />0 Yes C1 No N NA <br />[3 Yes [3 No ENA <br />L] Yes [j No BNA <br />Was fail-safe verified to be <br />oee oTlal?* <br />C3 Yes 13 No 0 NA <br />[j Yes E] No ENA <br />0 Yes 0 No ENA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />30 minutes <br />30 minutes <br />30 minutes <br />Test Start Time: <br />10,59 am <br />10:59 am <br />10:59 am <br />Initial Reading (Ri): <br />3.9278 <br />4,9984 <br />3,5741 <br />Test End Time: <br />11:14 am <br />11:14 am <br />11:14 am <br />Final Reading (RF): <br />3.9275 <br />4.8977 <br />3.5737 <br />Test Duration: <br />15 min, <br />15 min. <br />15 min. <br />Change in Reading (RF --Rt): <br />0.0003 <br />0.0007 <br />0.0004 <br />Pass/Fail Threshold or Criteria: <br />+/-0.002. <br />+/- 0.002" <br />+/- 0.002" <br />Test Result: <br />M Pass 0 Fail <br />0 Pass El Fail <br />ff, Past; Q Fail <br />Was sensor removed for testing? <br />09 Yes 0 No [I NA <br />rZ Yes El No [] NA <br />W Yes [3 No 0 NA <br />Was sensor properly replaced and <br />verified functional aft tvsting9 <br />9 Yes 1] No pNA <br />0 Yes 0 No 0 NA <br />IM Yes 13 No [3 NA <br />Comments — (include igformation on re airs made prior to testing, and recommended follow-up.for failed tests <br />"Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment testing scope of work", <br />If the entire depth of the sump is not tested, specify how much was tested. if the answer to am of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />901d 8888 826 80V swalsRs not-.Vjs aolAjas ZT:ST VTOE-EO-Ndf <br />
The URL can be used to link to this page
Your browser does not support the video tag.