My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
2701
>
2300 - Underground Storage Tank Program
>
PR0231176
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2023 4:14:10 PM
Creation date
6/3/2020 9:46:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231176
PE
2361
FACILITY_ID
FA0003798
FACILITY_NAME
MARCH LANE 76*
STREET_NUMBER
2701
Direction
W
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95219
APN
11619007
CURRENT_STATUS
01
SITE_LOCATION
2701 W MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231176_2701 W MARCH_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
356
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
•SAN1-JOAQUIN • Environmental Health Department <br /> -----COUNTY <br /> Underground Storage Tank Programinspection Report <br /> Facility Name: Facility Address: Date: <br /> MARCH LANE 76* 2701 W MARCH LN, STOCKTON December 14, 2017 <br /> -SUMMARY OF VIOLATIONS <br /> (GLASS I,CLASS It,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br /> The 5/6 Under Dispenser Containment(UDC)float and chain had the chain disconnected from the shear valve, <br /> preventing it from functioning properly and and not capable of detecting a leak at the earliest opportunity. <br /> Monitoring equipment shall be maintained to be able to detect a leak at the earliest possible opportunity. The chain <br /> was replaced by the service technician. Ensure that all monitoring equipment is maintained to detect a leak at the <br /> earliest opportunity. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> 309 CCR 2636(f)(1) Monitoring in sump/ UDC failed to activate an audible and visual alarm or stop the flow product. <br /> The Bravo box float and chain in the 5/6, 11/12 and 9/10 UDCs failed to stop the flow of product at the dispenser <br /> when tested. The 91 product in UDC 5/6 was found with the chain off, 87 product float and chain in UDC 6/5 and <br /> 11/12 were adjusted by the technician, 91 product float and chain in UDC 11/12 and 9/10 were adjusted by the <br /> technician and the diesel product float and chain in UDC 9/10 was replaced by the technician. All monitoring <br /> equipment shall be maintained to activate an audible and visual alarm or stop the flow of product at the dispenser <br /> when it detects a leak. The service technician verified functionality after the adjustments and replacement. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by January 13, 2018. <br /> Note: When they fail testing, spill buckets for the 87 and 91 fill shall be replaced with a spill bucket that has a <br /> minimum capacity of 5 gallons, is protected from galvanic corrosion, and has either a drain valve which allows <br /> drainage of the collected spill into the primary container or provides a mean to keep the spill container empty <br /> pursuant to CCR, Title 22, section 2635(b)(1). <br /> Kristopher Bell did not have his Bravo certification for the replacement of the float and chain, it will be provided <br /> through email once his records are found. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> FA0003798 PR0231176 SCO01 12/14/2017 <br /> EHD 23-01 Rev.10/31/2017 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.