My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003-2008
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
4511
>
2300 - Underground Storage Tank Program
>
PR0231216
>
COMPLIANCE INFO_2003-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 2:32:22 PM
Creation date
6/3/2020 9:46:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2008
RECORD_ID
PR0231216
PE
2361
FACILITY_ID
FA0002480
FACILITY_NAME
SHOP N GO 3
STREET_NUMBER
4511
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11023011
CURRENT_STATUS
01
SITE_LOCATION
4511 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231216_4511 PACIFIC_2003-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
347
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• UNIFIED PROGRAM CONSOLIDATED FORM <br /> • TANKS <br /> UNDERGROUND STORAGE TS-TANK PAGE 1 <br /> (Two pages per tank) <br /> Page of <br /> TYPE OF ACTION ❑ 1.NEW PERMIT ❑ 4.AMENDED PERMIT 5.CHANGE OF INFORMATION ❑ 6.TEMPORARY TANK CLOSURE 430. <br /> (Check one item only) ❑ 3.RENEWAL PERMIT ❑ 7.PERMANENTLY CLOSED ON SITE <br /> (Specifyrcason) (specifyrcason) ❑ 8.TANK REMOVED <br /> BUSINESS NAME(Saw wFACILITY NAME orDBA-DoimgBusincssAs) 3. FACILITY ID: 1 <br /> PCL e' ' M4nI - + `i- Ga Ir 0 ® d �4 J 1 ,9-1 <br /> LOCATION WIMINN SITE(Optional) (t 46 ®f b 0 S-q C) 431. <br /> 5 I 1 1" e-i C. e - I <br /> I.TANK DESCRIPTION <br /> A scaled plot plan with the location of the UST system including btlildin s and landmarks shall be submitted to the local agency.) <br /> TANK ID# 432. TANK MANUFACTURER 433. COMPARTMENTALIZED TANK [-]Yes No 434. <br /> If'Ycs,-complete one page for each congwt-t. <br /> DATE INSTALLED 435. TANK CAPACITY IN GALLONS 436. NUMBER OF COMPARTMENTS 437 <br /> (YEAR/MO) <br /> 9, 000 <br /> ADDITIONAL DESCRIPTION(For local use only) 438. <br /> H.TANK CONTENTS <br /> ,,,,TArNK USE 439- PETROLEUM TYPE 440. <br /> 1. MOTOR VEHICLE FUEL ❑la. REGULAR UNLEADED ❑2. LEADED ❑5.JET FUEL <br /> Ifchcckcd,completePcnokum Type) PCI b. PREMIUM UNLEADED ❑3. DIESEL ❑6. AVIATION GAS <br /> ❑ 2. NON-FUEL PETROLEUM ❑le. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER: <br /> ❑ 3. CHEMICAL PRODUCT COMMON NAME(from Hazardous Mate ish,inventory page) �1' CAS#(from Ha78rdous Materials Inventory page) 442. <br /> ❑ 4. HAZARDOUS WASTE <br /> (Includes Used Oil) <br /> ❑ 95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK [11. SINGLE WALL ❑3. SINGLE WALL WITH EXTERIOR ❑5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443. <br /> (Check one item only) MEMBRANE LINER ❑95. UNKNOWN <br /> 2. DOUBLE WALL ❑4. SINGLE WALL IN A VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank 1. BARE STEEL ❑3. FIBERGLASS/PLASTIC [15. CONCRETE ❑95.UNKNOWN 444. <br /> (Check one item only) ❑2. STAINLESS STEEL [14. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE ❑99.OTHER: <br /> REINFORCED PLASTIC(FRP) W/100%METHANOL <br /> TANK MATERIAL-secondary tank ❑1. BARE STEEL 03. FIBERGLASS/PLASTIC ❑8. FRP COMPTIBLE W/100%METHANOL 95.UNKNOWN 445. <br /> (Check one item only) ❑2. STAINLESS STEEL❑4. STEEL CLAD W/FIBERGLASS ❑9. FRP NON-CORRODABLE JACKET ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑10. COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING ❑1.RUBBER LINED ❑3.EPDXY LINING ❑5.GLASS LINING ❑95.UNKNOWN 446. DATE INSTALLED 447. <br /> OR COATING ❑2.ALKYD LINING ❑4.PHENOLIC LINING [16.UNLINED ❑99.OTHER <br /> (Check one item only) <br /> OTHER CORROSION ❑1.MANUFACTURED CATHODIC ❑3.FIBERGLASS REINFORCED PLASTIC ❑95.UNKNOWN 448. DATE INSTALLED 449. <br /> PROTECTION PROTECTION ❑4.IMPRESSED CURRENT ❑99.OTHER <br /> (IfA licable) Ej 2.SACRIFICIAL ANODE <br /> SPILL AND OVERFILL YEAR INSTALLED 45o. TYPE 451. OVERFILL PROTECTION EQUIPMENT: YEAR INSTALLED 452 <br /> (Check all that apply) 1.SPILL CONTAINMENT u 2.BALL FLOAT_ LJ 4.EXEMPT �T OFF VALVE <br /> .DROP TUBE , <br /> O 3.STRIKER PLATE <br /> IV.TANK LEAK DETECTION <br /> (A description of the monitoring m shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK 453. IF DOUBLE WALL TANK OR TANK WITH BLADDER 454. <br /> (Check all that apply) (Check one item only) <br /> ❑1.VISUAL(EXPOSED PORTION ONLY) ❑5.MANUAL TANK GAUGING(MTG) ❑1.VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2.AUTOMATIC TANK GAUGING(ATG) ❑6.VADOSE ZONE 10-2.CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3.CONTINUOUS ATG ❑7.GROUNDWATER ❑3.MANUAL MONITORING <br /> ❑4.STATISTICAL INVENTORY RECONCILIATION ❑8.TANK TESTING <br /> (SIR)+BIENNIAL TANK TESTING ❑99.OTHER <br /> V.TANK CLOSURE INFORMATION/ PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455. ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456. TANK FILLED WITH INERT MATERIAL? 457. <br /> gallons ❑Yes ❑ No <br /> UPCF hwfwre-b(1/99)-1/4 http://www.unidoesorg Rev.02/16/00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.