<br />CONTAINMENT:
<br />Sump Risers,
<br />Rings��
<br />�'� a; c� w�kj., ��'•t"° Seg "�i-2 p �aP` ..-�z6 ,� � q�
<br />HD
<br />L
<br />Monitor Welll
<br />With 2" Fittings
<br />Annular Space
<br />e
<br />500
<br />1,000
<br />1
<br />6-5 3/8"
<br />51"
<br />46"
<br />4,000
<br />3/16"
<br />675
<br />1,087
<br />4'-5 3/8"
<br />70"
<br />65"
<br />5,500
<br />3/16"
<br />1,000
<br />1,404
<br />6-5 3/8"
<br />70"
<br />65"
<br />8,000
<br />3/16"
<br />2,000
<br />2,319
<br />12'-4 5/8"
<br />70"
<br />65"
<br />15,500
<br />3/16"
<br />2,500
<br />2,777
<br />15-4 5/8"
<br />70"
<br />65"
<br />19,500
<br />3/16"
<br />3,000
<br />3,233
<br />18'-4 5/8"
<br />70"
<br />65"
<br />23,000
<br />3/16"
<br />3,000
<br />3,706
<br />8'-81/2"
<br />102"
<br />97"
<br />10,700
<br />3/16"
<br />4,000
<br />4,147
<br />24'-41/2"
<br />70"
<br />65"
<br />29,500
<br />1/4"
<br />4,000
<br />4,397
<br />11'-11/4"
<br />102"
<br />97"
<br />30,500
<br />3/16"
<br />5,000
<br />5,186
<br />13'-9 3/8"
<br />102"
<br />97"
<br />38,500
<br />1/4"
<br />6,000
<br />6,171
<br />17'-13/8"
<br />102"
<br />97"
<br />48,500
<br />1/4"
<br />8,000
<br />7,745
<br />22'-4 5/8"
<br />102"
<br />97"
<br />63,500
<br />1/4"
<br />10,000
<br />8,102
<br />15-101/2"
<br />134 3/8"
<br />129 3/8"
<br />78,000
<br />1/4"
<br />10,000
<br />9,124
<br />27'-0 5/8"
<br />102"
<br />97"
<br />77,000
<br />1/4"
<br />12,000
<br />9,306
<br />18'-111/2"
<br />134 3/8"
<br />129 3/8"
<br />93,900
<br />1/4"
<br />12,000
<br />10,698
<br />32'-3 7/8"
<br />102"
<br />97"
<br />92,500
<br />1/4"
<br />15,000
<br />14,177
<br />23'-7 7/8"
<br />134 3/8"
<br />129 3/8"
<br />118,000
<br />1/4"
<br />16,000
<br />14,877
<br />24'-41/2"
<br />134 3/8"
<br />129 3/8"
<br />125,400
<br />5/16"
<br />20,000
<br />17,680
<br />30'-3 3/8"
<br />134 3/8"
<br />129 3/8"
<br />155,000
<br />5/16"
<br />25,000
<br />24,348
<br />37'-71/4"
<br />134 3/8"
<br />129 3/8"
<br />190,000
<br />3/8"
<br />30,000
<br />27,277
<br />36-4 3/4"
<br />148
<br />143
<br />228,000
<br />3/8"
<br />40,000
<br />32,527
<br />49'-0"
<br />148
<br />143
<br />308,000
<br />3/8"
<br />Sample Specification The contractor shall provide the SuperTank® The primary tank shall be
<br />built to UL 58 construction standards with the full thickness of steel listed in Table 3.1 of UL 58. The pri
<br />tank shall be isolated from the external environment and secondarily contained by Fiberglass Reinforced '-
<br />Plastic (200 mil nominal thickness) which is not attached to the tank except at the fittings. The primary tank
<br />shall be factory tested to 5 psi internal pressure. Prior to shipment, the annular space shall be proof tested by
<br />vacuum only to 20" hg vacuum. The double wall tank shall have been tested in accordance with UL 1746
<br />and shall bear an external label indicating that the complete tank is UL listed as a jacketed secondary
<br />containment tank. Patent #5,047,101 and #5,102,005