Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
1301
>
2300 - Underground Storage Tank Program
>
PR0231342
>
COMPLIANCE INFO_1999-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2021 3:26:07 PM
Creation date
6/3/2020 9:46:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2009
RECORD_ID
PR0231342
PE
2361
FACILITY_ID
FA0000392
FACILITY_NAME
FLAMES LIQUOR
STREET_NUMBER
1301
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95242
APN
03104030
CURRENT_STATUS
01
SITE_LOCATION
1301 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231342_1301 W KETTLEMAN_1999-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
391
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
later that day (Attachment 3). <br />On October 25, 2005, Mr. Catanyag performed a routine inspection and witnessed the annual <br />monitoring system certification. Secondary containment testing was last performed on August 29, <br />2002 (Attachment 4) and was due by August 2005. The 87 and 91 octane leak detectors also failed. <br />An inspection report was left with Mr. Graffigna (Attachment 5). <br />On October 31, 2005, a permit application was submitted and approved to replace the 87 and 91 <br />octane leak detectors (Attachment 6). The leak detectors were replaced and tested under inspection <br />of this office on November 14, 2005, and a report was submitted to the EHD (Attachment 7). <br />On November 8, 2005, secondary containment testing was performed three months late, and the <br />diesel line and 91 octane piping sump failed (Attachment 8). A permit submitted for repairs on <br />January 3, 2006, was approved (Attachment 9). The diesel line and 91 octane piping sump were <br />retested under inspection of this office on January 16, 2006, and a report was submitted to the EHD <br />(Attachment 10). <br />On October 31, 2006, Mr. Ray von Flue, Sr. REHS, EHD, performed a routine UST inspection <br />(Attachment 11) and witnessed the annual monitoring system certification (Attachment 12). Water <br />was found in the diesel piping sump and removed by the technician on site. <br />On November 8, 2007, Mr. Garrett Backus, Sr. REHS, EHD, performed a routine UST inspection <br />(Attachment 13) and witnessed the annual monitoring system certification (Attachment 14). Two <br />shear valves on the dispensers would not trip when initially tested. They were adjusted and retested <br />on site. The monitoring system certification, leak detector testing, and spill container testing were <br />performed one month late, but were not noted on the inspection report. During the inspection, Mr. <br />Graffigna stated that this facility will be sold in December. On November 27, 2007, a service <br />request for a new owner UST consultation was submitted, though escrow had not closed on the sale <br />yet. A letter was mailed to the prospective owner (Attachment 15). <br />On January 7, 2008, Mr. von Flue received a call from Ms. Rupinder Padda, new owner, who stated <br />escrow was scheduled to close in about a week. Mr. von Flue asked her to call to schedule an <br />appointment for the UST consultation after escrow has closed. <br />On December 14, 2007, Ms. Padda paid the UST and hazardous waste facility transfer fees and <br />transferred the operating permit, which was valid through December 31, 2007 (Attachment 16). <br />On January 31, 2008, Mr. von Flue performed a UST consultation with Ms. Padda. Ms. Padda <br />completed all the ownership transfer forms and the property and tanks were transferred. <br />Attachments 17 and 18 include property owner information and tank owner information for the <br />former owner. <br />Attachments 19, 20, and 21 include property owner information and tank owner information for <br />the current owner, and the UST facility file narrative. <br />2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.