My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
1301
>
2300 - Underground Storage Tank Program
>
PR0231342
>
COMPLIANCE INFO_1999-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2021 3:26:07 PM
Creation date
6/3/2020 9:46:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2009
RECORD_ID
PR0231342
PE
2361
FACILITY_ID
FA0000392
FACILITY_NAME
FLAMES LIQUOR
STREET_NUMBER
1301
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95242
APN
03104030
CURRENT_STATUS
01
SITE_LOCATION
1301 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231342_1301 W KETTLEMAN_1999-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
391
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AML <br />SAN JOAdW COUNTY ENVIRONMENTAL HEALTH ARTMENT <br />UNDERGROUND STORAGE TANK <br />MONITORING PLAN -- PAGE 1 <br />TYPE OF ACTIONI NEW PLAN OF CHANGE INFORMATION <br />Mol. <br />PLAN TYPE MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. <br />M02. <br />(Check one item only) THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): <br />I. FACILITY INFORMATION <br />FACILITY ID # (Agency Use Only) <br />FACILITY NAME � talmes ���V�12.. C /�a�F <br />M03. <br />FACILITY SITE ADDRESS 1-60, w' Ke H+Crncar, L r\ MOS. <br />CITY <br />Mos. <br />U. EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br />State law requires that testing, preventive maintenance, and calibration of monitoring equipment (e.g., sensors, probes, line leak detectors, etc.) be performed in <br />M06 <br />accordance with the equipment manufacturers' instructions, or annually, whichever is more frequent. Such work must be performed by qualified personnel. <br />MONITORING EQUIPMENT IS SERVICED 1. ANNUALLY ❑ 99. OTHER (Specify): <br />M07. <br />III. MONITORING LOCATIONS <br />This monitoring plan must include a Site Plan showing the general tank and piping layouts and the locations where monitoring is performed (i.e., location of each sensor, <br />line leak detector, monitoring system control panel, etc.). If you already have a diagram (e.g., current UST Monitoring Site Plan from a Monitoring System Certification <br />form, Hazardous Materials Business Plan map, etc.) which shows all required information, include it with this plan. <br />IV. TANK MONITORING <br />MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S): (Check all that apply) <br />Mlo. <br />1. CONTINUOUS ELECTRONIC MONITORING OF TANK ANNULAR (INTERSTITIAL) SPACE(S) OR SECONDARY CONTAINMENT VAULT(S) <br />SECONDARY CONTAINMENT IS: alDRY ❑ b. LIQUID FILLED ❑ c. UNDER PRESSURE ❑ d. UNDER VACUUM <br />Ml1. <br />PANEL MANUFACTURER: M12 MODEL #: _'M G <br />[,7 <br />M13. <br />LEAK SENSOR MANUFACTURER: �L6�-%-z»R ,07- M14. MODEL #(S): --6s 2_0 <br />M15. <br />❑ 2. AUTOMATIC TANK GAUGING (ATG) SYSTEM USED TO MONITOR SINGLE WALL TANK(S) <br />PANEL MANUFACTURER: Ml6• MODEL #: <br />M17, <br />IN -TANK PROBE MANUFACTURER: M18- MODEL #(S): <br />MM <br />LEAK TEST FREQUENCY: ❑ a CONTINUOUS ❑ b. DAILY/NIGHTLY ❑ c. WEEKLY <br />M20. <br />❑ d. MONTHLY ❑ e. OTHER (Specify): Mei. <br />PROGRAMMED TESTS: ❑ a. 0.1 g.p h. ❑ b. 0.2 g.p h. ❑ c. OTHER (Specify): M22. <br />M23. <br />49-3- INVENTORY RECONCILIATION ❑ a MANUAL PER 23 CCR §2646 ❑ b. STATISTICAL PER 23 CCR §2646.1 <br />M24. <br />❑ 4. WEEKLY MANUAL TANK GAUGING (MTG) PER 23 CCR §2645 <br />TESTING PERIOD: ❑ a 36 HOURS ❑ b. 60 HOURS <br />M25. <br />❑ 5. INTEGRITY TESTING PER 23 CCR §2643.1 <br />TEST FREQUENCY: ❑ a ANNUALLY ❑ b. BIENNIALLY ❑ c. OTHER (Specify): M26. <br />MV. <br />❑ 6.VLSUAL MONITORING DONE: ❑ a DAILY ❑ b. WEEKLY (Rogn ma agcy amwwm) <br />❑ 99. OTHER (Specify): <br />M28. <br />V. PIPE MONITORING <br />MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) (Check all that apply) <br />Mao. <br />1. CONTINUOUS ELECTRONIC MONITORING OF PIPING SUMP(S)/TRENCH(ES) AND OTHER SECONDARY CONTAINMENT <br />SECONDARY CONTAINMENT IS: X a DRY ❑ b. LIQUID FILLED INC `- UNDER PRESSURE n d. UNDER VACUUM <br />Mat <br />PANEL MANUFACTURER: -. � ae wzs D M32 MODEL #:C� <br />M33. <br />LEAK SENSOR MANUFACTURER: /007" M34. MODEL #(S): OSP <br />M35. <br />WILL A PIPING LEAK ALARM TRIGGER AUTOMATIC PUMP (i.e., TURBINE) SHUTDOWN? a. YES ❑ b. NO <br />Mab <br />WELL FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGER AUTOMATIC PUMP SHUTDOWN? JR a YES ❑ b. NO <br />2. MECHANICAL LINE LEAK DETECTOR (MLLD) THAT ROUTINELY PERFORMS 3.0 h. LEAK TESTS AND RESTRICTS OR SHUTS <br />'07- <br />OFF <br />g.p <br />PRODUCT FLOW WHEN A LEAK IS DETECTED <br />MLLDMANUFACTURER(s): Vly]/ M38. MODEL #(S): GI9�v�0AD� FX I ✓ <br />M39. <br />❑ 3. ELECTRONIC LINE LEAK DETECTOR (ELLD) THAT ROUTINELY PERFORMS 3.0 g.p h. LEAK TESTS <br />ELLD MANUFACTURER: M40 MODEL #: <br />M41. <br />PROGRAMMED LINE INTEGRITY TESTS: ❑ a. MINIMUM MONTHLY 0.2 g p.h. ❑ b. MRQMUM ANNUAL 0.1 g p h. <br />M41 <br />WILL ELLD DETECTION OF A PIPING LEAK TRIGGER AUTOMATIC PUMP SHUTDOWN? ❑ a YES ❑ b. NO <br />Mai. <br />WILL ELLD FAILUREIDISCONNECTION TRIGGER AUTOMATIC PUMP SHUTDOWN? ❑ a YES ❑ b. NO <br />Moa. <br />❑ 4. INTEGRITY TESTING <br />TEST FREQUENCY: ANNUALLY ❑ b. EVERY 3 YEARS ❑ c. OTHER (Specify) Mas. <br />Mab. <br />❑ 5.VISUAL MONITORING DONE: ❑ a DAILY ❑ b. WEEKLY* ❑ c. MIN. MONTHLY & EACH TIME SYSTEM OPERATED** <br />Mal. <br />* Roquirca agency amxoval **Allowed for monimring ofunburiod cmorgmcy gammor faci piping onlypor WSC §25281.5(6)(3) <br />❑ 6. PIPING IS SUCTION PIPING MEETING ALL REQUIREMENTS FOR EXEMPTION FROM MONITORING PER 23 CCR §2636(a)(3) <br />❑ 7. NO PRODUCT OR REMOTE FILL PIPING IS CONNECTED TO THE UST(s) <br />❑ 99. OTHER (Specify) <br />Mos. <br />SJCEHD-d (07/03) -1/4 <br />07123/03 <br />
The URL can be used to link to this page
Your browser does not support the video tag.