COMPLIANCE INFO_1985-1998
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
401
>
2300 - Underground Storage Tank Program
>
PR0231346
>
COMPLIANCE INFO_1985-1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2023 3:50:07 PM
Creation date
6/3/2020 9:46:59 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-1998
RECORD_ID
PR0231346
PE
2361
FACILITY_ID
FA0003603
FACILITY_NAME
TESORO (SPEEDWAY XP) 68152
STREET_NUMBER
401
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04513019
CURRENT_STATUS
01
SITE_LOCATION
401 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231346_401 W KETTLEMAN_1985-1998.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
475
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
THE XLP...3LEAK TEST <br /> The Red Jacket XLP leak detector is hour)is metered through the XLP into flow to approximately 1-1/2 to 3 GPM. <br /> a pressure-sensing,piston-operated the piping system. If a leak is present This is the indication to the operator that <br /> valve designed to indicate a leak in the that equals or exceeds this amount,as a leak is present.' <br /> between the leak detector and much product If there are no leaks,pressure rapidly <br /> piping p escapes from the system <br /> the dispenser. as is metered in through the XLP. builds in the system forcing the XLP to <br /> When the line pressure is at approxi- Under this condition pressure cannot open to the full-flow position. In a <br /> system with no leaks,it takes approxi- <br /> mately less than 1 psi and the sub- build up in the piping system. When a mately two seconds for a complete test. <br /> merged pump is turned on,a controlled nozzle is opened,a poppet in the XLP No further line testing takes place until <br /> amount of product(three gallons per moves to a position that restricts the the line pressure drops below 1 psi. <br /> \\ sm <br /> Ir <br /> Position 1 Position 2 <br /> Position 3 <br /> Vented Vented Mented <br /> ID Tank to Tank to Tank <br /> Pressure Relief / <br /> valve 2422 PSI <br /> Less than i <br /> 1 PSi <br /> Full Pressure Full Pressure \ Full Pressure <br /> PoppetApprox.25 PSI Approx.25 PSI \� Approx.25 PSI <br /> 4+from Pump \ 4-n from Pump 4—from Pump <br /> Metering Pin \ \\ <br /> \\ I PSI / \� 20 to 22 PSI/ \\\ \\\ AN Pressure <br /> To x\\\\\\\\\\\\� <br /> Discharge tine IT.Discharge Line ITO Discharge Line <br /> 1. The Trip or Relaxed Position. Under 2. Leak Sensing Position. As the If there is no leakage in the system,the <br /> normal operating conditions,it is pressure builds to approximately 20 to 22 small flow around the metering pin <br /> assumed that the lines are filled with psi(rapidly)the piston has moved the increases the Fine pressure to 22 psi in <br /> gasoline. When the system pressure is poppet to such a position as to almost approximately two seconds at which <br /> less than 1 psi,the piston and poppet are stop the flow into the piping through the point the piston will snap the poppet to <br /> in their'down*or"tripped"position. The XLP valve poppet. In this position,all Position 3,allowing full flow. Any product <br /> position of the valve poppet is such as to the flow must then travel around the relieved through pressure relief valve <br /> allow approximately 1-112 to 3 GPM flow metering pin which limits it to approxi- during trip position will be vented through <br /> into the delivery line through a bypass mately 3 GPH rate. If a simultaneous vent tube to tank. This allows piston to <br /> opening in the XLP valve poppet when loss from the system equals or exceeds move freely with no back pressure to <br /> the submersible pump starts. Since the this amount,the line pressure will not hamper its movement <br /> system is full,pressure builds rapidly and build beyond this point and the valve will 3. Non-Leak Position. This position allows <br /> the poppet moves to the leak sensing remain in the leak sensing position with full flow. The poppet will remain in this <br /> position assuming there is no leak the main flow blocked. If there is an position as long as the sytem pressure <br /> present. The pressure relief valve attempt to dispense while the valve is in remains above 1 psi. At less than t psi, <br /> prevents any build up of pressure under this position,the line pressure will drop, the poppet will return to Position 1 and <br /> piston when in trip position by allowing the piston will respond,and the poppet the next time the pump is activated,the <br /> relief of trapped product will return to Position 1 where the 1-1/2 XLP will perform a lire test <br /> to 3 GPM will flow to the dispensers.' <br /> 'If the dispensing system(the solenoid valve and the nozzle)is opened previous to the completion of the line test,the XLP will detect this opening <br /> as a leak and restricted flow will result. Closing of the nozzle(s)for a period of time,adequate to allow completion of the fine test,well allow the XLP <br /> to open. This,in tum,will allow full flow providing there is no additional escape for fuel in the system. <br /> ® Per the above process, this product Is designed and sold to detect leaks of approximately 3GPH or <br /> greater only. For leaks of less than approximately 36PH,please consult with your Marley Pump Company <br /> representative. <br /> XLP-31010/92 MQRLEY <br /> TME MARLEY PUMP COuPANY <br /> ♦Onson b ins uaney Com' <br />
The URL can be used to link to this page
Your browser does not support the video tag.