Laserfiche WebLink
ORODUCT SPECIFICATION SHEET <br /> FOR 4,000 THRU 12,000 GALLON <br /> UNDERWRITERS LABORATORIES LISTED, TYPE I, SECONDARY <br /> CONTAINMENT, DOUBLE STEEL WALL, FIBERGLASS LAMINATED, UNDERGROUND <br /> STORAGE TANKS FOR FLAMMABLE AND COMBUSTIBLE LIQUIDS. <br /> SEE CHART FOR OVERALL LENGTH <br /> 3 3/4" 12" 18" 18" AS REO'D 18' 112'13_3/4" <br /> TANK <br /> MONITOR/ t OPTIONAL I OPTIONAL MONITOR/ <br /> VENT I 4" NPT OPENING MANWAYVENT <br /> ONE END OF THE ( I <br /> TANK IS LABELED I I I <br /> WITH SHIPPING <br /> WEIGHT,GALLON <br /> CAPACITY,AND <br /> STEEL THICKNESS <br /> Q <br /> O <br /> os <br /> � I <br /> PRIMARY CONTAINMENT <br /> SECONDARY CONTAINMENT OPTIONAL STRIKER PLATE <br /> CAPACITY AND SIZE CHART <br /> MODEL NOMINAL GALLONS ACTUAL GALLONS OVERALL SHIPPING <br /> NUMBER PRIMARY CONTAINMENT PRIMARY CONTAINMENT LENGTH WEIGHT <br /> 42 4,000 4,011 11'-9" 9,445 <br /> 52 5,000 5,045 14'-6" 10,560 <br /> 62 6,000 6,298 17'-10" 12,235 <br /> 82 8,000 8,272 23'-0' 15 310 <br /> 102 10,000 10,027 27'-9" 18 230 <br /> 122 12,000 12,001 33'•0" 21,285 <br /> STANDARD TANK DESCRIPTION: <br /> • Tank design meets or exceeds industry standards, Underwriters Laboratories, Federal, and State standards. <br /> • Primary and Secondary Containments are fabricated of thick, new steel plate. <br /> • The Primary Containment is standard with five(5)4" NPT couplings. <br /> • The Secondary Containment is standard with two(2)2" NPT monitor/vent tank flanges. <br /> • Two(2) lifting lugs. <br /> • <br /> All shell joints are continuously welded, using automatic submerged arc welding processes. <br /> • The Primary Tank is air tested at a minimum of 5 PSI prior to assembly with the Secondary Containment. <br /> • Upon completion of primary and secondary containment assemblies, both containments are air tested at a minimum <br /> of 5 PSI. <br /> • The exterior surface of the Secondary Containment is sandblasted and laminated with a controlled thickness of <br /> reinforced fiberglass (polyester resin and fiberglass mat), for a superior corrosion barrier. The lamination is Holiday <br /> tested at 35,000 volts prior to shipping and prior to unloading at installation site. <br /> • Each Trusco Secondary Containment Tank is provided with installation instructions, temporary shipping covers on <br /> all openings, field fiberglass kit, calibrated gage chart, 13'-0"calibrated (1")gage stick, and 30-year warranty. <br /> OPTIONAL ACCESSORIES: <br /> 0 Manways • Manway Extensions • Additional 4"NPT Primary Openings • Striker Plates Hold Down Straps <br />