My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
401
>
2300 - Underground Storage Tank Program
>
PR0231346
>
COMPLIANCE INFO_1999-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2023 3:51:40 PM
Creation date
6/3/2020 9:47:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2005
RECORD_ID
PR0231346
PE
2361
FACILITY_ID
FA0003603
FACILITY_NAME
TESORO (SPEEDWAY XP) 68152
STREET_NUMBER
401
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04513019
CURRENT_STATUS
01
SITE_LOCATION
401 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231346_401 W KETTLEMAN_1999-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
306
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FIED PROGRAM CONSOLIDATED-IV TANK <br /> --UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br /> L'n <br /> I 1 11 11 INNIS Paw_ of <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE 1.PRESSURE D 2 SUCTION 0 3.GRAVITY0 1.PRESSURE El 2 SUCTION D 3.GRAOTY 459 <br /> [I <br /> CONSTRUCTION I I SINGLE WALL % i_195 3,LINED TRENCH 0 OTHER 460 D 1.SINGLE WALL ,UNKNOWN 462 <br /> MANUFACTURER 0 2 DOUBLE WALL [195 UNKNOWN 0 2 DOUBLE WAI L [199.OTHER <br /> MANUFACTURER Teleflex 461 MANUFACTURER 463 <br /> [I I RARE STEEL C1 6 FRP COMPATIBLE w1109% METMANOL (I t BARE STEEL 0 6 FRP COMPATIBLE WIIW%METHANOL <br /> 0 2 STAINLESS STEEL 0 7 GALVANIZED STEEL [I UKNOWN D 2. STAINLESS STEEL 0 7 GALVANIZED STEEL <br /> []3,PLASTIC COMPATIBLE W1 CONTENTS 0 99. OTHER C1 3- PLASTIC COMPATIBLE WICONTENIS 0 8.FLEXIBLE(HOPE) 0%. OTHER <br /> 0 4 FIBERGLASS 0 8.FLEXIBLE(HOPE) C1 4. FIBERGLASS ❑S.CATHODIC PROTECTION <br /> 0 5,STEEL WICOATING 0 9.CATHODIC.PROTECTION 464 05 STEEL WICOATING ❑95.UNKNOWN 465 <br /> 000 <br /> X-94 A WNW <br /> ON.�A� <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466 SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(check an miwy), PRESSURIZED PIPING{Check all that apoy), <br /> 0 1 ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST 0.'H,AUTO PUMP SHUT OFF FOR 0 1 ELECTRONIC LINE LEAK DETECTOR 3A GPH TEST WITH AUTO PUMP SHUT OFF FOR <br /> LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION=AUDIBLE AND VISUAL LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION-AUDIBLE AND VISUAL <br /> ALARMS. ALARMS <br /> 02. MONTHLY 0.2 GPH TEST 0 2MONTHLY 0 2 GPH TEST <br /> [13 ANNUAL INTEGRffY TEST(O.IGPH) (33. ANNUAL INTEGRITY TEST(0.IGPH) <br /> A 04. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS jchKk ap"apply) <br /> [15. DAILY VISUAL MONITORING OF PUMPING SYSTEM-TRIENNIAL PIPING INTEGRITY <br /> TEST(0.1 GPH) C35. DAILY VISUAL MONITORING OF PIPING AND PJMHNG SYSTEM <br /> SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNOPtPING): C1 6, TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> 0 7. SELF MONITORING SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING) <br /> GRAVITY FLOW 07. SELF MONITORING <br /> 09. BIENNIAL INTEGRITY TEST(0.1 GPH) GRAVITY FLOW(CWJ as mim apply) <br /> [18. DAILY VISUAL MONITORING <br /> Q9. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all thal apply) PRESSURIZED PIPING(Check all thai apply) <br /> I& CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND 10, CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL.ALARMS AND <br /> (Clock om) (Chm*0") <br /> Da. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS 0 a AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> [3b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM Ob AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION DISCONNECTION <br /> E3c. NO AUTO PUMP SHUT OFF Oc NO AUTO PUMP SHUT OFF <br /> 0 11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TER WITH FLOW SHUTOFF OR <br /> [1 <br /> RESTRICTION 11, AUTOMATIC LEAK DETECTOR <br /> 0 12. ANNUAL INTEGRITY TEST(0.1 GPH) 012. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> i <br /> SUCTOVGRAVITY SYSTEM SUCTIONIGGIRAVITY SYSTEM I <br /> 0 13. CONT HPOUS SUMP SENSOR-AUDIBLE AND VISUAL,ALARMS 013. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGE14CY GENERATORS ONLY(Che*as haat apply) EMERGENCY GENERATORS ONLY(Cheek as that appPy) <br /> [114. CONTINUOUS WW SFNSOFI ffljMff AUTO PUMp SHUT OFF.AUDIBLE AND 014. CONTINUOUS SUMP SENSOR ffit9i AUTO PUMP SHUT OFF-AU09BLE AND <br /> VISUAL ALARMS VISUAL ALARMS <br /> 0 IS.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)MLHW FLOW SHUT OFF OR <br /> (3 <br /> RESTRCTION ❑15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> 0 16. ANNUAL INTEGRITY TEST(0.1 GPH) [316. ANNI INTEGRITY TEST(0.1 GPH) <br /> El 17. DAILY VISUAL CHECK 017. DAILY VISUAL CHECK <br /> CONTAROAENT 01. FLOAT MECKqM THAT SHUTS OFF SHEAR VALVE 0 4.ONLY MSW CHIECK <br /> DATE INSTALLED 469 El Z CONTINLIOUS DISKUM PAN SENSOR-AUDIBLE AND VISUAL ALARMS El S.TRENCH UNEIR I MONITORING <br /> i9ffl 03. CONTINUOUS DISPENSER PAN SENSOR M AUTO SHUT OFF FOR DISPENSER <br /> VISUAL 0 6.NONE 4w <br /> ALARMS <br /> ml a to ft bW d xv knoaftftc <br /> ME OF 0WfW-WR*WWM_R <br /> Robert E. Hoover P*90 EnWorwneinital AdministraW <br /> PW"*EVin0o 00%(For IcW un wM <br /> 476 <br /> UPCF 0/99 MWSed) Fortrorly SWRCS Form 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.