My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
401
>
2300 - Underground Storage Tank Program
>
PR0231346
>
COMPLIANCE INFO_1999-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2023 3:51:40 PM
Creation date
6/3/2020 9:47:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2005
RECORD_ID
PR0231346
PE
2361
FACILITY_ID
FA0003603
FACILITY_NAME
TESORO (SPEEDWAY XP) 68152
STREET_NUMBER
401
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04513019
CURRENT_STATUS
01
SITE_LOCATION
401 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231346_401 W KETTLEMAN_1999-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
306
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br /> n <br /> TEST DATE:03/16/04 8900 SHOAL CREEK,BUILDING 200 WORK ORDER NUMBER2230433 <br /> CLIENT:USA PETROLEUM AUSTIN,TEXAS 78757(512)451-6334 SITE:USA #3513 <br /> Tank ID: #1 1 Tank manifolded: No Bottom to top fill in inches: 142.0 <br /> Product: SUPREME Vent manifolded: YES Bottom to grade in inches: 148.5 <br /> Capacity in gallons: 14,130 Vapor recovery manifolded: YES Fill pipe length in inches: 46.0 <br /> Diameter in inches: 96.00 Overfill protection: YES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 456 Overspill protection: YES Stage I vapor recovery: DUAL <br /> Material: DW STEEL Installed: ATG Stage II vapor recovery: ASSIST <br /> CP installed on: <br /> COMMENTS <br /> Start(in) End )(inNew/passed Failed/replaced New/passed Failed/replaced <br /> Dipped Water Level: 0.00 (in) <br /> L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> Dipped Product Level: 36.75 36.75 <br /> Probe Water Level: -0.006 -0.006 Make: <br /> Ingress Detected: Water N Bubble N UllageN Model: <br /> Test time: 11:20-12:46 S/N: <br /> Inclinometer reading: 0.00 Open time in sec: <br /> Holding psi: <br /> VacuTect Test Type: single tank Resiliency cc: NOT NOT <br /> VacuTect Probe Entry Point: Fill Test leak rate ml/m: TESTED TESTED <br /> Pressure Set Point: -0.50 Metering psi: <br /> Tank water level in inches: 0.00 Calib.leak in gph: <br /> Water table depth in inches: 148.50 Results: <br /> Determined by(method): SURVEY <br /> Result: PASS <br /> COMMENTS <br /> COMMENTS <br /> NO WELL, TANK IS A DRY ANNULAR SYSTEM. <br /> MEASUREMENT USED IS TANK BOTTOM DEPTH. <br /> Material: DW FIBERG <br /> Diameter(in): 2.0 <br /> Length(ft): 100.0 <br /> Test psi: <br /> Bleedback cc: <br /> Test time(min): NOT NOT NOT NOT <br /> Start time: TESTED TESTED TESTED TESTED <br /> End time: <br /> Final gph: <br /> Result: <br /> Pump type: PRESSURE <br /> Pump make: RED JACKET <br /> COMMENTS Impact Valves Operational: <br /> Printed 03/23/2004 09:58 <br />
The URL can be used to link to this page
Your browser does not support the video tag.