COMPLIANCE INFO_1999-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
401
>
2300 - Underground Storage Tank Program
>
PR0231346
>
COMPLIANCE INFO_1999-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2023 3:51:40 PM
Creation date
6/3/2020 9:47:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2005
RECORD_ID
PR0231346
PE
2361
FACILITY_ID
FA0003603
FACILITY_NAME
TESORO (SPEEDWAY XP) 68152
STREET_NUMBER
401
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04513019
CURRENT_STATUS
01
SITE_LOCATION
401 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231346_401 W KETTLEMAN_1999-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
306
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUAL TANK INFORMATION TEST RESULTS <br /> TanknoloW <br /> TEST DATE:02/04/03 8900 SHOAL CREEK,BUILDING 200 WORK ORDER NUMBER2225298 <br /> CLIENT:USA PETROLEUM AUSTIN,TEXAS 78757(512)451-6334 SITE:USA 3513 <br /> `fii�1�1W �l <br /> Tank ID: #1 1 Tank manifoided: No Bottom to top fill in inches: <br /> Product: SUPREME Vent manifolded: YES Bottom to grade in inches: <br /> Capacity in gallons: 14,130 Vapor recovery manifolded: YES Fill pipe length in inches: <br /> Diameter in inches: 96.00 Overfill protection: YES Fill pipe diameter in inches: <br /> Length in inches: 456 Overspill protection: YES Stage I vapor recovery: DUAL <br /> Material: DW STEEL Installed: ATG Stage 11 vapor recovery: ASSIST <br /> CP installed on: <br /> COMMENTS <br /> 7 TIF.#sTFtFSUITS T M ceu est: !. SUL: Testmethod: PTA, <br /> Start(in) End(in) Nowipassed Failed/replaced New/passed Failed/replaced <br /> Dipped Water Level: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> Dipped Product Level: Make: RED JACKET <br /> Probe Water Level: Model: may <br /> Ingress Detected: Water Bubble Ullage S/N: 112990246 <br /> Test time: Open time in sec: 2.00 <br /> Inclinometer reading: Holding psi: 18 <br /> VacuTect Test Type: NOT Resiliency in ml: 95 NOT <br /> VacuTect Probe Entry Point: TESTED Test leak rate ml/m: 189.0 TESTED <br /> Pressure Set Point: Metering psi: 18 <br /> Tank water level in inches: Calib.leak in gph: 3.00 <br /> Water table depth in inches: Results: PASS <br /> Determined by(method): <br /> Result: COMMENTS <br /> COMMENTS <br /> t fi TSULTSty! <br /> Test 'pe: PTK 88 <br /> Material: DW FIBERG <br /> Impact Valves Operational: YES Diameter(in): 2.0 <br /> Length(ft): 100.0 <br /> COMMENTS Test psi: 60 <br /> Bleedback cc: 150 <br /> Test time(min): 30 <br /> Test 1:Start time: 10:56 <br /> Finish psi: 52 NOT NOT NOT <br /> Vol change cc: 20 TESTED TESTED TESTED <br /> Test 2:Start time: 11:07 <br /> Finish psi: 54 <br /> Vol change cc: 18 <br /> Test 3:Start time: 11:18 <br /> Finish psi: 55 <br /> Vol change cc: 14 <br /> Final gph: 0.027 <br /> Result: PASS <br /> Pump type: PRESSURE <br /> Pump make: RED JACKET <br /> Printed 02/21/2003 08:56 MSHAW <br />