My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
401
>
2300 - Underground Storage Tank Program
>
PR0231346
>
COMPLIANCE INFO_2006-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2023 3:55:06 PM
Creation date
6/3/2020 9:47:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2012
RECORD_ID
PR0231346
PE
2361
FACILITY_ID
FA0003603
FACILITY_NAME
TESORO (SPEEDWAY XP) 68152
STREET_NUMBER
401
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04513019
CURRENT_STATUS
01
SITE_LOCATION
401 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231346_401 W KETTLEMAN_2006-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
299
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MAR-24-2010 08:18 Service Station Systems 408 938 8888 P.05 <br /> I <br /> Monitoring I System Certification-Pug 3 <br /> Site Address- 401 W. Kettleman Ln. Date of Testing/Servicing: 2124110 <br /> F. In-Tank Gauging I SIR Equipment: cl check this box if tank gauging is used only for inventory control. <br /> 13 Check this box if no tank gaughigOTSIR equipment is installed. <br /> This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. <br /> Com lets the Mowing checklist; <br /> 0 yes -C3 No* Has all input wiring been inspected for proper entry and termination,including testing for ground faults? <br /> 13 Yes a No* Were all tank gauging probes visually inspected for damage and residue buildup? <br /> o Yes 0 No* Was accuracy of system product level readings tested? <br /> a Yes 0 No* Was accuracy of system water level readings tested? <br /> a Yes 13 No* I were all probes reinstalled property? <br /> o yes E3 No*_1 Were all items on the equipment manufacturer's maintenance checklist completed? <br /> In Section H below,describe how and when these deficiencies were or will be corrected. <br /> G. Line Leak Detectors(]LLD): 0 Check this box if LLD's are not installed. <br /> Cpm lets the following checklist: - .1) <br /> *yes a No* For equipment start-up or annual equipment certification was a leak simulated to verify LLD performance? <br /> 0 N/A (Check all that apply)ply) Simulated leak reate:IX 3 g.p.h.(I.); M 0.1 g.p.h.(2,),, 0 0.2 g.p.h_(2.). <br /> Notes- 1. Required for equipment start-up certification and annual certification, <br /> 2. Unless mandated!?Z local agency,certification required only for electronic LLD start-up. <br /> IS Yes 1 0 No* Were all LLD's confirmed operational and accurate within regulato!j requirements? <br /> (X Yes a No* Was the testin&apparatus pro RS Ul calibrated? <br /> la Yes 13 No* For mechanical LLD's,does the LLD restrict product flow if it detects a leak? <br /> El N/A <br /> 0 Yes Cl No* For electronic LLD's,does the turbine automatically shut off if the LLD detects a leak? <br /> M N/A <br /> Ei Yes 0 No* for electronic LLD's, does the turbine automatically shut off if any portion of the monitoring system is disabled <br /> M N/A or disconnected? <br /> 0 Yes 0 No* For electronic LLD's, does the turbine automatically shut off ifanyportion of the monitoring system <br /> 11 N/A malfunctions or fails a test? <br /> 13 Yes 13 No* For electronic LLD's,have all accessible wiring connections been visually inspected? <br /> ix N/A <br /> 11 Yes 0 NO Were all items on the equipment manufacturefs maintenance checklist completed? <br /> InSection H below,describe how and when these deficiencies were or will be corrected. <br /> H. Comments: <br />
The URL can be used to link to this page
Your browser does not support the video tag.