My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
401
>
2300 - Underground Storage Tank Program
>
PR0231346
>
COMPLIANCE INFO_2006-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2023 3:55:06 PM
Creation date
6/3/2020 9:47:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2012
RECORD_ID
PR0231346
PE
2361
FACILITY_ID
FA0003603
FACILITY_NAME
TESORO (SPEEDWAY XP) 68152
STREET_NUMBER
401
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04513019
CURRENT_STATUS
01
SITE_LOCATION
401 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231346_401 W KETTLEMAN_2006-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
299
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MAR-23-2011 11:37 Service Station Systems 408 938 8888 P.05 <br /> 10 40 <br /> Monitoring System Certification-Page 3 of 3 <br /> Site Address: 401 W. Kettleman Ln. Date:of Testing/SeMcing: 2/23/11 <br /> E. in-Tank Gauging/SIR Equipment: 0 Cheek this box if tank gauging is used only for inventory control. <br /> ❑ Check this box if no tank gauging or SIR equipment is installed. <br /> This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. <br /> Com lug checklist; <br /> 0 Yes R No* Has all input wiring been inspected for proper entry and termination,including testing for ground faults'? <br /> ❑ Yes 0 No* Were all tank gauging probes visually inspected for damage and residue buildup? <br /> 0 Yes 0 No* Was accuracy of system product level readings tested? <br /> 13 Yes ❑ No* Was accuracy of system water level readings tested? <br /> ❑ yes ❑ No* Were all probes reinstalled properly? <br /> 0 Yes Q No* Were all items on the equipment manufacturers maintenance checklist completed! <br /> *in Section H below,describe how and when these deficiencies were or will be corrected. <br /> G. Line Leak Detectors(LLD): 0 Check this box if LLO's are not installed. <br /> Cum lets the folio ng checklist: <br /> 3 Yes 0 No* For equipment start-up or annual equipment certification was a leak simulated to verify LLD performance? <br /> ❑ N/A (Check all that apply) Simulated leak rate: 0 3 g.p.h.(l.); ❑ 0.1 g.p.h.(2.); D 0.2 g.p.h.(2.). <br /> Notes: 1. Required for equipment start-up certification and annual certification. <br /> 2. Unless mandated bX local agency,certification required only for electronic LLD start-u . <br /> C1 Yes 0 No* Were all LLD's confirmed o erational and accurate within regulatory r uirements? <br /> r❑ <br /> I3 Yes 13 No* Was the testing apparatus ro crl calibrated'? <br /> � Yes 0 No* For mechanical LLD's,does the LLD restrict product flow if it detects a leak? <br /> 0 N/A <br /> Yes ® No* For electronic LLD's,does the turbine automatically shut off if the LLD detects a leak? <br /> N N/A <br /> Q Yes ❑ No* For electronic LLD's,docs the turbine automatically shut off if any portion of the monitoring system is disabled <br /> M N/A or disconnected? <br /> 0 Yes 0 No* For electronic LLD's,does the turbine automatically shut off if any portion of the monitoring system <br /> W N/A malfunctions or fails a test? <br /> Llyy13No* for electronic LLD's,have all accessible wiring connections been visually inspected'? <br /> 9 N/A <br /> (3 No* Were all items on the equipment manufacturer's maintenance checklist completed? <br /> *In Section H below,describe how and when these deficiencies were or will be corrected. <br /> H. Comments: LLD Tester that was used during initial testing(passed)on 2/23/11 did not have a Calibration Sticker. <br /> Returned on 3/18/11(Bryan Lundien)and retested all LLD's(passed) <br />
The URL can be used to link to this page
Your browser does not support the video tag.