Laserfiche WebLink
n <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sj oq v.org/ehd <br />{, a�fs� `.}��. .°„ ,, fif4i ���i�t.: �; IrJ :'V i��"._ s, _ 4� ., ,;- <br />"!M "111 <br />}�Ci 3 20 1 *�'ilC 4 �yY�l ,[y� r <br />}V�74,1W_ <br />lV,.„ <br />�,✓.ia, <br />.,- <br />_ <br />n , z,©A, ki4`„) ml <br />„ti <br />Facility Name: Facility Phone: <br />Date: <br />TESORO (MOBIL) 68152 (209) 368-8787 <br />February 23, 2017 <br />Facility Address: <br />CERS ID: <br />401 W KETTLEMAN LN, LODI, CA 95240 <br />10181231 <br />Inspection Contact: <br />Title: <br />Phone: <br />Stephen Coulter <br />Environmental Compliance <br />(209) 368-8787 <br />Inspection Type: <br />Program: <br />ROUTINE INSPECTION - Operating Permit <br />2361 - UST FACILITY <br />Consent For: <br />I Consent Given By: <br />® Inspection ® Photos ® Sample <br />I Patty Moreno, Manager <br />Service Technician Onsite: Exp. Date: <br />Designated Operator: Exp. Date: <br />Kristopher Bell 08/24/2018 <br />Kaylynn Rammell 06/15/2018 <br />Service Technician Manufacturer's Training <br />VMI LDT890, 11/11/18; Veeder root TLS-3XX, 05/11/17 <br />CCR= a i ornia Codeo egu a ions HSC=Health and Safely7 Code CFR= Code of a era Regulations <br />V = Violation R = Repeat violation COS = Corrected on site during inspection <br />�3l <br />it=ii.3. <br />;.*".. 3::':rvyC'... i:r .S-a� `y_ f. m� ��R ii�:ri. ::.._— tx *'.:4 '.. '.�.-1' ��. <br />. 1.. £_ $ 3.� N. r', - h . ala �i inw v 4r % ,.a."at ni�i� <br />c e•,..i"`,. -� r a .:n,, �i ,,.Vi ?,t ';i z .vs t.. ”- <br />r....i."i <br />..�i it <br />3 y 1: I Min Y� r �r. 1 <br />t ?' ggl <br />It n i.: <br />i�;:. r'. z n;�x ,, „ j:� .,, s .._ t ...- <br />Q'11l:_ ,N,:i 4 ,. -, <br />,rn(3rf,�r �<<.r;g4 <br />,rt,s4. os3 Ir „�.�,4 <br />101 <br />HSC 25284 <br />No permit to operate <br />❑ V ❑ R ❑ COS <br />102 <br />HSC 25284(a)(3) <br />No written agreement between tank owner and tank operator to monitor the tank system <br />❑ V ❑ R ❑ COS <br />103 <br />HSC 25292.2 <br />Current financial responsibility documents not submitted <br />❑ V ❑ R ❑ COS <br />104 <br />CCR 2711 <br />UST operating permit application for facility and tank information not submitted or current <br />❑ V ❑ R ❑ COS <br />105 <br />CCR 2632(d)(1) <br />Failed to have an approved UST monitoring plan <br />❑ V ❑ R ❑ COS <br />106 <br />CCR 2632(d)(2) <br />Failed to have an approved UST response plan <br />❑ V ❑ R ❑ COS <br />107 <br />CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or failed to completely show where monitoring is performed <br />■ V ❑ R ❑ COS <br />108 <br />CCR 2637(f), 2638(e) <br />Failed to notify the EHD 48 hours prior to conducting testing <br />❑ V ❑ R ❑ COS <br />109 <br />CCR 2637 <br />Failed to test secondary containment <br />❑ V ❑ R ❑ COS <br />110 <br />CCR 2637(e) <br />Failed to submit secondary containment test report within 30 days <br />❑ V ❑ R ❑ COS <br />111 <br />CCR 2638(a) <br />Failed to test monitoring and leak detection equipment annually <br />❑ V ❑ R ❑ COS <br />112 <br />HSC 25284.2 <br />Failed to test spill containers annually <br />❑ V ❑ R ❑ COS <br />113 <br />CCR 2638(d) <br />Failed to submit monitoring system certification test report within 30 days <br />❑ V ❑ R ❑ COS <br />114 <br />CCR 2636(f) <br />Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down <br />❑ V ❑ R ❑ COS <br />115 <br />CCR 2715(a) <br />Failed to inform the EHD of designated operator identification or change within 30 days <br />❑ V ❑ R ❑ COS <br />116 <br />CCR 2715 <br />Designated operator, service tech or installer did not possess current ICC certification <br />❑ V ❑ R ❑ COS <br />117 <br />CCR 2663 <br />Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after <br />❑ V ❑ R ❑ COS <br />118 <br />CCR 2663 <br />Failed to submit tank lining certification within 30 days or to conduct proper tests <br />❑ V ❑ R ❑ COS <br />119 <br />HSC 25299 <br />Documents were falsified or misrepresented <br />❑ V ❑ R ❑ COS <br />120 <br />CCR 2635(d) <br />Failed to submit UST Certification of Installation/Modification <br />❑ V ❑ R ❑ COS <br />121 <br />CCR 2712(f) <br />Failed to submit a written response within 30 days of receiving an inspection report <br />❑ V ❑ R ❑ COS <br />122 <br />CCR 26310) <br />Failure to submit UST system component statement of compatibility for substance stored <br />❑ V ❑ R ❑ COS <br />A� edli�:Fr9y <br />!kk�.. <br />T`+ _ <br />9 r121 <br />201 <br />CCR 2712(b) <br />Failed to maintain alarm logs and/or records of follow up actions <br />❑ V ❑ R ❑ COS <br />202 <br />CCR 2712(b) <br />Failed to maintain cathodic protection test records on site for at least 6 1/2 years <br />❑ V ❑ R ❑ COS <br />203 <br />CCR 2712(b) <br />Failed to maintain records of monitoring, repair, lining, and upgrades on site <br />❑ V ❑ R ❑ COS <br />FA0003603 PR0231346 SCO01 02/23/2017 <br />EHD 23-01 Rev. 09/22/16 Page 1 of 4 Underground Storage Tank Program OIR <br />