My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-1998
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
601
>
2300 - Underground Storage Tank Program
>
PR0231348
>
COMPLIANCE INFO_1997-1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2023 9:44:21 AM
Creation date
6/3/2020 9:47:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-1998
RECORD_ID
PR0231348
PE
2361
FACILITY_ID
FA0003803
FACILITY_NAME
KETTLEMAN CHEVRON
STREET_NUMBER
601
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04728006
CURRENT_STATUS
01
SITE_LOCATION
601 E KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231348_601 E KETTLEMAN_1997-1998.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
575
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORN* WATER RESOURCES CONTR OARD <br /> FORM `B': UNDERGROUND STORAGE TANK PRO RAM 'T <br /> TANK TANK PERMIT APPLICATION INFORMATION <br />!4 <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑2 INTERIM PERMIT ❑4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE 8 TANK REMOVED D 9 <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: LjN Q cjkl__ FARM TANK-YES❑ NO <br /> • <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY <br /> A. OWNERS TANK ID# &0 kV5 R C)6?j I B. MANUFACTURED BY: Ut-4 K4N <br /> E'er' <br /> C. YEAR INSTALLED O&Z I i9D. TANK CAPACITY IN GALLONS: 10 Go <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. 1 MOTOR VEHICLE FUEL F] 2 PETROLEUM B. C• 1 UNLEADED E 2 LEADED 3 DIESEL <br /> ❑3 CHEMICAL PRODUCT ❑ 4 OIL IJ ' PRODUCT ❑4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑5 HAZARDOUS ❑80 EMPTY ❑ 95 UNKNOWN ❑2 WASTE El 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A.TYPE OF ❑1 DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER 95 UNKNOWN <br /> SYSTEM F-]2 SINGLE WALLED 4 SECONDARY CONTAINMENT [-]99 OTHER <br /> 011'STEELIIRON ❑2 STAINLESS STEEL ❑3 FIBERGLASS ❑4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑5 CONCRETE ❑6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑8 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑99 OTHER <br /> C. INTERIOR 1 RUBBER LINED 2 ALKYD LINING F-] 3 EPDXY LINING [:]4 PHENOLIC LINING <br /> LINING ❑5 GLASS LINING F-1 6 UNLINED 95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? E]YES ❑ NO ❑99 OTHER <br /> D.CORROSION ❑ 1 POLYETHLENE WRAP ❑2 TAR OR ASPHALT ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑91 NONE 95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A.SYSTEM TYPE A U 1 SUCTION A(U2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B.CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A 095 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A O 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P095 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/7Y ) 2. ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> 9 19 SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ❑YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICA S NAM (PRINTED&SIGNATURE) V (�w \A l' A164 TE <br /> �ssaz. 01461 -7 11-1 90 <br /> LOCAL AGENC USE ONLOV UNOC.IA.L. <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID]ODE DD13Yg D <br /> CURRENT LOCAL AGENCY FACILITY ID# APPROVED BY NAME PHONE#WITH AREA C <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> CHECK# PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT# <br /> IFF'V <br /> FORM B(6-29-88) THIS FORM MUST BE ACCOMPANI A FACILITY/SITE APPLICATION, FORM`A',UNLESS A RENT FORMAHAS BEEN FILED <br /> DATA.PROCESSING COPY <br />
The URL can be used to link to this page