My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-1998
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
601
>
2300 - Underground Storage Tank Program
>
PR0231348
>
COMPLIANCE INFO_1997-1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2023 9:44:21 AM
Creation date
6/3/2020 9:47:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-1998
RECORD_ID
PR0231348
PE
2361
FACILITY_ID
FA0003803
FACILITY_NAME
KETTLEMAN CHEVRON
STREET_NUMBER
601
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04728006
CURRENT_STATUS
01
SITE_LOCATION
601 E KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231348_601 E KETTLEMAN_1997-1998.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
575
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORIo <br /> WATER RESOURCES CONT110'BOARD y °: f <br /> FORM W: UNDERGROUND STORAGE TANK PROGRAM A <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑3 RENEWAL PERMIT ❑5 CHANGE OF INFORMATION ❑7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑2 INTERIM PERMIT ❑4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE 8 TANK REMOVED Q/ <br /> - E <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED:Ul _ t FARM TANK Y S❑ N O <br /> o � <br /> d <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY <br /> WAS <br /> A. OWNERS TANK ID# O(iE5-tKj o- 1000 B. MANUFACTURED BY: <br /> I C. YEAR INSTALLED 19 162D. TANK CAPACITY IN GALLONS: <br /> 11. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. W <br /> A. ❑ 1 MOTOR VEHICLE FUEL ❑2 PETROLEUM B. C. ❑ 1 UNLEADED ❑2 LEADED ❑3 DIESEL <br /> ❑3 CHEMICAL PRODUCT4 OIL ❑ ljPRODUCT ❑4 GASAHOL ❑5 JET FUEL ❑6 AVIATION GAS <br /> ❑5 HAZARDOUS ❑80 EMPTY ❑95 UNKNOWN 2 WASTE ❑ 7 METHANOL ❑99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C.A.S.W <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A.TYPE OF ❑ 1 DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER 95 UNKNOWN <br /> SYSTEM ❑2 SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> 1 STEEL/IRON ❑2 STAINLESS STEEL ❑3 FIBERGLASS ❑4 STEEL CLADW/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑5 CONCRETE ❑6 POLYVINYLCHLORIDE ❑ 7 ALUMINUM ❑8 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑99 OTHER <br /> ❑ <br /> C. INTERIOR 1 RUBBER LINED El ALKYD LINING E] 3 EPDXY LINING ❑4 PHENOLIC LINING <br /> LINING ❑5 GLASS LINING ❑6 UNLINED %UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑99 OTHER <br /> D.CORROSION ❑ 1 POLYETHLENE WRAP ❑2 TAR OR ASPHALT ❑ NYL WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑91 NONE 95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A.SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A 40 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B.CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C.MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A®95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S 1 VISUAL CHECK &S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P Q 95 UNKNOWN P S 99 OTHER <br /> V1. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> ) ® SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? [::]YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF�MeY�KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLI ANTS AME(PRINTED&SIGNATURE) J O NN(n�� I�,�'VE4 kA.Lzr' DATE <br /> Awe Iv s � l /n /90 <br /> LOCAL AGEN Y USE ONLY Ut i o6 L") <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> l3 � I EF1oa131q <br /> CURRENT LOCAL AGENCY FACILITY ID# APPROVED BY NAME PHONE#WITH AREA CODE <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> CHECK# PERMIT AMOUNT SURCHARGE AMT. FEE CODERECEIPT# J <br /> FORM B(6-29-88) THIS FORM MUST BE ACCOMPANI Y A FACILITY/SITE APPLICATION, FORM'A',UNLESS A u RENT FORMA' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.