Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
601
>
2300 - Underground Storage Tank Program
>
PR0231348
>
COMPLIANCE INFO_1997-1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2023 9:44:21 AM
Creation date
6/3/2020 9:47:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-1998
RECORD_ID
PR0231348
PE
2361
FACILITY_ID
FA0003803
FACILITY_NAME
KETTLEMAN CHEVRON
STREET_NUMBER
601
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04728006
CURRENT_STATUS
01
SITE_LOCATION
601 E KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231348_601 E KETTLEMAN_1997-1998.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
575
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ah Ah <br /> INDIVIDu ANK/LINEILEAK DETECTOR TM REPORT <br /> TEST DATE: 08/03/98 WORK ORDER NUMBER: 2205566 <br /> CLIENT: WENDT CONSTRUCTION SITE: CHEVRON #97065 <br /> IMISIM MM <br /> Tank ID:dsl 4 Material:Dw STEEL Bottom to top fill in inches: 173.0 <br /> Product:DIESEL Tank manifolded:No Bottom to grade fill in inches: 181.0 <br /> Capacity in gallons: 10,152 Vent manifolded:No Fill pipe length in inches: 78.0 <br /> Diameter in inches: 95.00 Vapor recovery manifolded:No Fill pipe diameter in inches: 4.0 <br /> Length in inches: 335 Impact Valves Operational: y Stage I vapor recovery: NONE <br /> Tank age(years): Overfill protection: yEs Stage II vapor recovery: NONE <br /> Fuel pure rating: Overspill protection: yEs Installed: ATG <br /> COMMENTS CP installed on: <br /> an n n New/passed Failed/replaced New/passed Failed/replaced <br /> Dipped Water Level: 0.25 0.25 L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> Dipped Product Level: 67.00 67.00 Make:VEEDERROOT <br /> Probe Water Level: 0.012 0.012 Model: P.L.D. <br /> Ingress Detected: Water N Bubble N UllageN S/N: <br /> Test time: 10:37-12:08 Open time in sec: <br /> VacuTect Test Type: single tank Holding psi: <br /> VacuTect Probe Entry Point: rill Resiliancy cc: <br /> Pressure Set Point: -1.80 Test leak rate ml/m: 189.0 <br /> Tank water level in inches: 0.00 Metering psi: 10 <br /> Water table depth in inches: 200.00 Calib. leak in gph: 3.00 <br /> Determined by(method): sURVEy Results: PASS <br /> Result: P,/+ss <br /> COMMENTS COMMENTS <br /> V/R PLLD INSTALLED. <br /> MENEM= <br /> Material: Dw FISERG <br /> Diameter(in): 2.0 <br /> Length(ft): 100.0 <br /> Test psi: 50 <br /> Bleedback cc: 75 <br /> Test time(min): 30 <br /> Test 1:Start time: 12:30 <br /> Finish psi: 48 <br /> Vol change cc: 17 <br /> Test 2:Start time: 12:40 <br /> Finish psi: 50 <br /> Vol change cc: 0 <br /> Test 3:Start time: 12:50 <br /> Finish psi: 50 <br /> Vol change cc: 0 <br /> Final gph: 0.009 <br /> Result: PASS <br /> Pump type: PRESSURE <br /> COMMENTS Pump make: FE PETRO <br /> 8900 SHOAL CREEK,BUILDING 200,AUSTIN,TEXAS 78757(512)451-6334 Draft 08/06/98 12:32 MSHAW <br />