My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-1998
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
601
>
2300 - Underground Storage Tank Program
>
PR0231348
>
COMPLIANCE INFO_1997-1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2023 9:44:21 AM
Creation date
6/3/2020 9:47:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-1998
RECORD_ID
PR0231348
PE
2361
FACILITY_ID
FA0003803
FACILITY_NAME
KETTLEMAN CHEVRON
STREET_NUMBER
601
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04728006
CURRENT_STATUS
01
SITE_LOCATION
601 E KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231348_601 E KETTLEMAN_1997-1998.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
575
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />I <br />i <br />24b. COEFFICIENT OF EXPANSION <br />digits <br />Name of Supplier. Ownen or Dealer <br />Address No. and Streetts) <br />City State <br />Date of Test <br />15. TANK TO TEST 15a. BRIEF DIAGRAM OF TANK FIELD <br />_ i I J' <br />Identity by position <br />�e�,. <br />f <br />—T-� <br />Brand and Grade <br />17. FILL -UP FOR TEST <br />Stick Water Bottom I j I t( <br />before Fill -up I - in. y L. in. <br />to %- Gallons Tank Diameter <br />16. CAPACITY <br />Nominal Capacity <br />j Gallons <br />By most aocurate <br />capacity chart available <br />18. SPECIAL CONDITIONS AND PROCEDURES TO TEST THIS TANK ❑ Water in tank ❑ Limits) being tested with LVLLT <br />See manual Sections applicable. Check below and record procedure in log (27). ❑ High water table in tank excavation <br />use maximum allowable test pressure for all tests. 19. TANK MEASUREMENTS FOR <br />,our pound rule does not apply to doubiewalled tanks. <br />TSTT ASSEMBLY <br />Complete section below <br />1. Is four pound rule required? <br />2. Height to 12" mark trom bottom of tank <br />3. Pressure at bottom of tank <br />4. Pressure at top of tank <br />Bottom of tank to grade' ............................ .% in. <br />^do 30" for -r' probe easy.... ....................... 30 in. <br />(� <br />yYes❑ � Total tubing to assemble —approximate ............. 1 +` ✓ in. <br />in. <br />r r; <br />in <br />20. EXTENSION HOSE SETTING <br />Tank top to grade' ........................ <br />Extend hose on suction tube 6" or more <br />below tank top ............................ <br />'If Fill pipe extends above grade, use top of fill. <br />USE WITH THERMAL SENSOR <br />PN5039 (Blue Box) <br />22. Thermal -Sensor reading after circulation <br />23. Digits per °F in range of expected change <br />jr <br />in. <br />IF <br />in. <br />Gallons <br />From <br />❑ <br />24b. COEFFICIENT OF EXPANSION <br />digits <br />Station Chart <br />❑ <br />_{ <br />r <br />Tank Manufacturer's Chart <br />® <br />Engineering <br />��� <br />Company Data <br />❑ <br />Temperature in Tank <br />D <br />Chans supplied with Tank Tester <br />❑ <br />Other <br />Inventory in Tank <br />Water Bottom <br />Top off equipment <br />Total Quantity <br />Total Gallons <br />ea. Reading <br />21. VAPOR RECOVERY SYSTEM ❑stage <br />I ❑ stage it <br />24b. COEFFICIENT OF EXPANSION <br />digits <br />RECIPROCAL METHOD <br />_{ <br />r <br />Type of Product ........................................ <br />��� <br />Hydrometer Employed .................................. <br />H <br />Temperature in Tank <br />D <br />After Circulation ........... <br />! ' "' °F <br />Temperature of Sample ................................. <br />`" °F <br />,. tC <br />`' ' <br />Difference ('/-) ......................................... <br />,F <br />24a. IF USING THERMAL SENSOR DTS-2000 <br />OR OC -2000 WHICH READ 1000 DIGITS <br />PER OF TRANSFER 1000 TO LINE 26, <br />DIGITS PER OF IN TEST RANGE. <br />'A <br />area. <br />Rater to N.F.P.A. 30, Sections 2-3.2.4 and 2-7.2 and the tank <br />manufacturer regarding allowable system test pressures. <br />24c. FOR TESTING WITH WATER see Table C & D <br />Water Temperature after Circulation r <br />Table C from Thermal Sensor ............................ ~' °F <br />Coethlent of Water <br />.Table D ................................................ <br />Added Surfactant? ❑ yes [D No Transfer COE to Line 25b. F <br />25. (a) ° r k (b) r = (C) P J I gallons <br />Total quantity in Coefficient of expansion for Volume change in this tank <br />full tank (17) involved product per °F <br />26. It <br />..i This is <br />Volume change per °F 125 or 24b) Digits per ° F in test Volume change per digit test <br />Observed A.P.I. Gravity ................................. <br />' <br />digits <br />Reciprocal PageLl <br />_{ <br />x <br />Total quantity in - Reciprocal <br />Volume change in <br />digits <br />full tank (17) <br />this tank per °F <br />Transfer to Line 26s. <br />24a. IF USING THERMAL SENSOR DTS-2000 <br />OR OC -2000 WHICH READ 1000 DIGITS <br />PER OF TRANSFER 1000 TO LINE 26, <br />DIGITS PER OF IN TEST RANGE. <br />'A <br />area. <br />Rater to N.F.P.A. 30, Sections 2-3.2.4 and 2-7.2 and the tank <br />manufacturer regarding allowable system test pressures. <br />24c. FOR TESTING WITH WATER see Table C & D <br />Water Temperature after Circulation r <br />Table C from Thermal Sensor ............................ ~' °F <br />Coethlent of Water <br />.Table D ................................................ <br />Added Surfactant? ❑ yes [D No Transfer COE to Line 25b. F <br />25. (a) ° r k (b) r = (C) P J I gallons <br />Total quantity in Coefficient of expansion for Volume change in this tank <br />full tank (17) involved product per °F <br />26. It <br />..i This is <br />Volume change per °F 125 or 24b) Digits per ° F in test Volume change per digit test <br />
The URL can be used to link to this page
Your browser does not support the video tag.