HUNTER ENVIRONMENTAL: SERVICES, INC. <br />18350 MT. LANGLEY STREET, SUITE 101 <br />FOUNTAIN VALLEY, CA 92708 <br />800-247-9014 800-247-2186 <br />CUSTOMER: UNOCAL <br />ADDRESS: 601 E. Kettleman <br />Lodi, CA <br />FINAL TEST RESULTS <br />TEST DATE: 9-30-87 <br />,ME`�'TA►- HEALTH <br />EIVVIK�"rel l /SERVICES, <br />k ER LOCATION/IDENTIFICATION NO.: 6015 <br />TEST RESULTS SUMMARY <br />OCT 211987 <br />R. L. FOL DA, <br />LEAK LOKATOR RESULTS <br />SYSTEM TANK SIZE WATER LEVEL ALR <br />NO. PRODUCT GALLONS DiA/MATL INCHES INCHES GPH CONCLUSION RECOMMENDATIONS <br />1 Super <br />10000 <br />95"/ST <br />0 <br />160 <br />+.032 <br />Tight <br />2 UA <br />10000 <br />9511/ST <br />.25 <br />156 <br />-.015 <br />Tight <br />3 Diesel <br />10000 <br />95"/ST <br />0 <br />155 <br />-.029 <br />Tight <br />OTHER INFO: Tank bottom shields in place. No drop tube or leak detector on diesel. U/L taped off <br />at 1:30. Impact valve held open with wire on UA full serve. <br />PRODUCT LiNES - HYDROSTATIC PRESSURE TEST RESULTS <br />SYSTEM TYPE OF PUMP POUNDS POUNDS MINUTES PRODUCT PRODUCT CONCLUSION <br />NO. PRODUCT REMOTE SUCTION APPLIED HELD HELD LOSS CC's LOSS GPH /RESULT <br />1 Super Red Jacket 50 10 Pass <br />2 UA Red Jacket 50 10 Pass <br />3 Diesel Red Jacket 50 10 Pass <br />NOTE: On suction systems, NEVER put more than 15 psi on any pump system. <br />DETAIL OF TEST RESULTS <br />TEST <br />TIME <br />LEAK RATE TEMPERATURE <br />ABSOLUTE <br />CHECK <br />SYSTEM TEST LEVEL <br />CLOCK DURATION <br />COMPENSATION <br />LEAK RATE <br />TEST <br />NO. PRODUCT N0. (IN.) <br />STATE (HR-MiN) <br />CC/DIV CC/MiN DELTA of CC/MIN <br />CC/MIN GPH <br />Y/N <br />1 Super <br />1 160 9:50 <br />41 Min <br />.928 <br />+17.85 +.038 +15.82 <br />+2.02 <br />+.032 N <br />2 UA <br />1 156 2:35 <br />24 Min <br />.555 <br />+ 8.20 +.022 +9.159 <br />-.951 <br />-.015 N <br />3 Diesel <br />1 155 8:35 <br />32 Min <br />.608 <br />- 1.84 +.000 -- <br />-1.84 <br />-.029 N <br />*LEVEL <br />- Inches from Tank Bottom to Test <br />Level <br />ALR <br />- Absolute Leak Rate (Measured Leak <br />Rate <br />- Temperature Compensation) <br />in Gallons <br />Per Hour <br />CONCLUSION - NFPA 329 criterion of <br />+/- 0.05 <br />GPA is <br />used to certify tightness <br />CERTIFICATION <br />This Is to" certify -that the above tank systems were tested, using the HUNTER ENVIRONMENTAL SERVICES, INC* LEAK <br />LOKATOR according to all standard operating procedures. Those indicated as tight at full system meet the criterion <br />established by the National Fire Protection Association Pamphlet 329 for Precision Testing. <br />Tests Conducted and Certified By: Test Van No. 30 <br />Team Manager: Rudy Roessler <br />Tank Testing Specialist: Roger Renko <br />