Laserfiche WebLink
ULIULC Listed Red ThreadOt <br /> A Piping System <br /> GENERAL SPECIFICATIONS <br /> Primary Piping Secondary Containment Piping <br /> SCOPE SCOPE <br /> PIPE—Pipe shall be manufactured by Smith Fibercast by a PIPE—Pipe shall be manufactured by Smith Fibercast by a <br /> filament winding process using a thermosetting epoxy resin filament winding process using a thermosetting epoxy resin <br /> to impregnate strands of continuous glass filaments which to impregnate strands of continuous glass filaments which <br /> are wound around a mandrel at a prescribed helix angle and are wound around a mandrel at a prescribed helix angle and <br /> under controlled tension. All pipe All be supplied with under controlled tension. <br /> matching tapered T.A.B."A (Threaded and Bonded)coupling <br /> and spigot ends or T.A.B.spigot x spigot ends. CONSTRUCTION <br /> 3"-6"PIPE—RED THREAD 11A pipe shall have continuous <br /> CONSTRUCTION glass fibers filament wound at a 54'And angle in a matrix <br /> 2"-4"PIPE—RED THREAD IIA pipe shall have continuous of epoxy resin. Pipe shall be in compliance With ASTM <br /> glass fibers filament wound at a 54'And angle in a matrix D2310 and classified by its designation code. Pipe shall <br /> of epoxy resin. Pipe shall be in compliance with ASTM meet all performance requirements and mechanical <br /> D2310 and classified by its designation code. Pipe shall properties,and shall be classified with the following <br /> meet all dimensional and performance requirements, designation codes: <br /> mechanical properties,and shall be classified with the Size Designation Code at 73.4°F <br /> following designation codes: 3- RTRP-11AF <br /> Size Designation Code at 73.4°F RTRP-11AH <br /> T-3- RTRP-1 1AF <br /> 4- RTRP-1 1 AH ITEMS <br /> 3"-6"PIPE—Glass fiber reinforced filament wound pipe with <br /> ITEMS Plain end by Plain end or T.A.B.spigot by spigot ends. Pipe <br /> 2"-4"PIPE—Glass fiber reinforced filament wound ripe with to be factory prooftested at the following pressures: <br /> matching tapered T.A.B.(Threaded and Bonded)coupling 3"-300 psig(minimum) <br /> and spigot ends or T.A.B.spigot by spigot ends. Pipe to be 4"-265 psig(minimum) <br /> factory prooftested at the following pressures: 6"-265 psig(minimum) <br /> 2®-375 psig <br /> 3"-300 psig W-6"FITTINGS—Compression molded two-piece fittings <br /> 4--265 psig shall be manufactured using a vinyl ester molding <br /> 2"-4"FITTINGS—Compression molded fittings shall be compound. The molding compound shall be reinforced with <br /> manufactured using an epoxy molding compound. The a minimum of 60%chopped glass fiber. <br /> molding compound shall be reinforced with a minimum of ADHESIVES—Adhesive and curing agents shall be either <br /> 45%chopped glass fiber. In-line fittings are filament wound. UL Listed 8000 or 7000 series adhesive. Consult Smith <br /> Fibercast's installation manual No.B2160 for recommended <br /> ADHESIVES—Adhesive and curing agents shall be either heat curing techniques. <br /> UL Listed 8000 or 7000 series adhesive. <br /> Consult Smith Fibercast's installation manual No.B2160 for JOINING TECHNIQUES <br /> recommended heat curing techniques. 3"-6"PIPE and FITTINGS—Pipe shall be joined with either <br /> JOINING TECHNIQUES 8000 or 7000 series adhesive. Fittings shall be joined with <br /> either 7000 or 8000 series adhesives and filler. Material to <br /> 2"A"PIPE and FITTINGS—Pipe and fittings shall be joined be installed in accordance with Smith Fibercast's installation <br /> with 8000 or 7000 series adhesive using matching tapered manual No.82160. <br /> bell/coupling and spigot. Material to be installed in <br /> accordance with Smith Fibercast's installation manual No. TESTING <br /> B2160. 3"-6"SECONDARY CONTAINMENT PIPE SYSTEMS— <br /> Secondary containment pipe systems should be tested prior <br /> TESTING to use to assure soundness of all joints and connections. <br /> 2"A�'PRIMARY PIPE SYSTEMS—Primary pipe systems Consult Smith Fibercast's installation manual No.B2160. <br /> should be tested prior to use to assure soundness of all <br /> joints and connections. Consult Smith Fibercast's <br /> installation manual No.B2160. Note:6*secondary containment pipe and fittings are not ULAJLC tasted. <br /> 10 <br />