Laserfiche WebLink
1. Training for Ameron 1. Installation training for Ameron Dualoy 3000/L piping systems, including <br /> Dualor Piping Systems secondarily contained systems and Dualoy 3000/LCX,shall be done by an <br /> Ameron employee,sales representatve or distributor. <br /> 2. Training shall,at minimum,consist of a thorough review of the installation <br /> instructions(Bulletins,7501,8702 and/or 9903)as applicable for the systems <br /> on which the installer is to be certified. It is recommended that an installation <br /> video,(such as"Dualoy 3000/LCX Installation")be used during the training <br /> session. Also recommended is an examination of the installation tools,a <br /> demonstration of the joint preparation and bonding and,if possible,a"hands- <br /> on"execution of the installation procedures for a sample connection. <br /> 3. Upon completion of the training,each individual being trained shall complete the <br /> written examination for the systems on which they are to receive qualification. <br /> 4. The examinations will be signed by the trainee and the instructor and forwarded <br /> to Ameron for grading and registering of the individual as a"Certified Installer." <br /> 5. Ameron will issue a training certificate with the individual identified and will <br /> include their name on a registration list. Wallet-sized certificates and hard hat <br /> stickers may also be provided.Training certifications are valid for 3 years <br /> ii. Glossary &Abbreviations SC—Secondary containment fittings or pipe MV—Motor vehicle fuels <br /> NV—Normal vent line from tank CF—Concentrated fuels <br /> PC—Primary Carrier HB—High blend fuels <br /> PS—Primary/Secondary combined into one unit AM—Aviation and marine fuels <br /> VR—Vapor recovery <br /> iii. Pressure Ratings & Dualoy 3000/1- pipe specifications and ratings <br /> Specifications of <br /> Products Pipe Size Nominal O.D. Wall Thickness Weight Pressure Rating <br /> (inches) (inches) (inches) Ib/ft (inches) <br /> 2 2.38 .080 .5 200 <br /> 3 3.50 .085 .7 200 <br /> 4 4.50 .090 1.0 175 <br /> 6 6.63 .120 1.9 140 <br /> Dualoy 3000/1- couplings &adapters ratings <br /> Pipe Size Couplings Adapters BxF Adapters SxM Adapters SxF <br /> (inches) (psig) (psig) (psig) (psig) <br /> 2 200 200 200 200 <br /> 3 125 125 125 125 <br /> 4 100 100 100 100 <br /> 6 100 100 100 100 <br /> Dualoy 3000/1-fittings & adapters ratings <br /> Pipe Size 45°,90° Elbows Reducer Bushings Tees Adapters BxM <br /> (inches) (psig) (psig) (psig) (psig) <br /> 2 200 200 200 200 <br /> 3 125 125 125 125 <br /> 4 100 100 100 100 <br /> 6 100 100 100 100 <br /> 2-Piece Clamshell Fittings <br /> Pipe Size Dualoy 30001 Dualoy 3000/L Dualoy 3000/LCX <br /> (inches) Repair Coupling Containment Fittings Containment Fittings <br /> 2 200 — 50.. <br /> 3 125 50 20 <br /> 4 100 50 20 <br /> 2 6 100 50 — <br /> **Pressure rating with stiffening rings. <br />