Laserfiche WebLink
0 0 <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.s0qov.or_q/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Facility Facility Inspection <br /> Name: Lodi Food & Liquor Address: 1225 W. Lockeford St. Lodi, CA Nov 20, 2013 <br /> e: A Date: <br /> Facility Title: <br /> Contact: Jaspal Koont I owner 333-1038 <br /> Inspection X Routine X Monitoring System Certification 11 Installation ii Complaint—ID#: XOther: <br /> Type: Revised 11-22-13 <br /> (Authority HSC 25289) <br /> Consent for: XInspection XSampling XPhotos Granted by:Zulfiqar Khan Title: Manager <br /> Monitoring Piping Overfill <br /> Panel: INCON TS-1000 System: XPressurized []Suction E]Gravity Prevention: XMechanical 11 Audible/visual <br /> usT 5_ <br /> -Product -91-octane -----]---------------------------- ------------- -------------- ------------ <br /> -I-------------- <br /> 1_ 87 octane diesel -I- <br /> Designated ICC Exp. <br /> Operator: Kelvin Cruz Date: 10-25-15 Violations: El M1-Release Detection 11 M2-Release Prevention XM3-Both <br /> On site service CICC Exp'2-1 1-15 Manufacturer's vmi1-8-15, incon 11-2-14 <br /> Technician: Kelvin Cruz Date: Training: <br /> VIOLATIONS <br /> HSC=California Health and Safety Code;CCR=California Code of Regulations <br /> # C1 C2 M Code Section C1=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> EM=M W ENNERREM <br /> 101 HSC 25284 No permit to operate <br /> 102 HSC 25404.5 Annual operating fees not paid <br /> 103 HSC 25284(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br /> monitor the tanks stem <br /> 104 HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department(EHD) <br /> 105 CCR 2711 Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form) <br /> 106 CCR 2632(b) Monitoring Program(Monitoring&Response Plans)is not current or approved by the EHD <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or fails to completely show where monitoring is performed <br /> CR 2637 Secondary containment:(a)test not performed;(e)test report not submitted within 30 days;(f)test notification <br /> 101, C not provided to the EHD at least 48 hours prior to conducting the test <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 days; <br /> 109 CCR 2638 (e)test notification not provided to the EHD at least 48 hours prior to conducting an installation,repair, <br /> replacemen,calibration,or certification <br /> 110 HSC 25291 Annual line leak detector test not performed (MI) <br /> ill HSC 25284.2 Annual spill containment testing not performed <br /> 112 CCR 2636(0(4) Annual line tightness test not performed if positive shutdown or fail safe not present (MI) <br /> 113 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br /> 115 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br /> permit conditions <br /> 116 HSC 25292.5 Enhanced leak detection(ELD)testing not performed on a system located within 1000'of public well,or <br /> failures not repaired and retested <br /> 117 CCR 2661 Permit to repair UST system not obtained <br /> 118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br /> 119 HSC 25298(b) Permit to temporarily dose UST system not obtained <br /> 120 HSC 25298(c) Permit to dose UST system not obtained <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6%years,written <br /> performance claims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> 201 x CCR 2712(b) upgrades for the life of the tank. Monitoring records include:(1)date and time of all monitoring or sampling; <br /> (2)monitoring equipment calibration and maintenance records;(3)results of any visual observations;(4) <br /> results of sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other monitoring <br /> equipment,ground water elevations,or other test results;(6)results of inventory readings and reconciliations <br /> 202 1 CR 2712(1) I Monitoring plan,response plan,and/or operating permit and all conditions not onsite <br /> ul <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eight hours (Mi) <br /> L2O3 CCR 2650 was not recorded;(e)escaped secondary containment,not cleaned up after eight hours,or a sudden loss of <br /> product was not reported to the EHD within 24 hours <br /> Inspector Received By, Title: <br /> Aris Cacapit (209) 468-3453 <br /> EHD 23-02 Rev 04/19/12 Page 1 UST INSPECTION REPORT <br />