My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOCKEFORD
>
1225
>
2300 - Underground Storage Tank Program
>
PR0231350
>
COMPLIANCE INFO_2009-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 1:38:11 PM
Creation date
6/3/2020 9:47:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2015
RECORD_ID
PR0231350
PE
2361
FACILITY_ID
FA0003690
FACILITY_NAME
LODI FOOD & LIQUOR*
STREET_NUMBER
1225
Direction
W
STREET_NAME
LOCKEFORD
STREET_TYPE
ST
City
LODI
Zip
95240
APN
03710002
CURRENT_STATUS
01
SITE_LOCATION
1225 W LOCKEFORD ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231350_1225 W LOCKEFORD_2009-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
481
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGrE TANK SYSTEM <br /> DESIGNATED UST OPERATOR. MONTHLY INSPECTION REPORT <br /> Facility Name: Lodi Food & Liquor I spection 7Date: .j,—/9 Z /Z <br /> Facility Address: 1225 Lockford Street tty: LodName of Designated UST Operator Conducting Inspection: WZ <br /> International Code Council Certification No.: ( z _ on Date: <br /> _. Phone: (916) 371-2380 ext. <br /> Signature: <br /> N/A=Not A licable <br /> MONITORING PAW/ALARM HISTORY Yes No N/A <br /> Item ❑ <br /> 1, is the moni oring systemowered on and in ro er o eratin m de? ❑ <br /> 2. Is the mollitorina s stem not current! showin an leak alarms ❑ <br /> 3. Is the Alarm History Report/log for the previous month availab e,and has it been reviewed by the <br /> Designated US'r O erator? Attach a co o the alarm histo re ort/lo to this ins ection orm. <br /> 4. Has each alarm for the rUK <br /> evious month been res onded to appropriately? <br /> skip <br /> UST SYSTEM INSI' CTION <br /> 5. Ace tank top containment sumps free of water,debris,and haz rdous substance? ,vote:�frhe ans,ver to/rein a,vas"Yes," and <br /> to!tern 6.Suutps inhere an alarm has occurred ht the past month must be t spected tf a qualtfied service techntciun has not responded to urr <br /> ro erl addressed,die cause o the alarm.Documentation vert in a�n•o r late servfce should be attached to this r•e ort. Ye: NO <br /> Ye; No <br /> Sum Location: Su Location: ❑ ` <br /> Sump Location: Sul np Location: <br /> 6. Ares ill buckets(containment structures)free of water,debris and hazardous substance? Yes No N/A <br /> nk i lU Yes No N/A — <br /> Ta —87 Ta&4 ID— �— <br /> Tank 2 1D—91—_!—^ _- Ta k 5 ID— <br /> Tank 3 IU— � 'f a k ti IIS"— � ❑ ❑ <br /> 7. Are under-dispenser containment areas free of water,debris,ai id hazardous substance. Yes No N/A <br /> _ Yes No N/A <br /> El <br /> Dis enser— 1/2 Di enser— - <br /> Dispenser—3/4Di enser— <br /> —� Dieer— ❑ <br /> Q <br /> Dins <br /> Dispenser--5/6 ns ` I <br /> Dis enser—7/8 eer— <br /> 8. Leak detection is p operly located within under-dis enser cont inment. yes NoN/A i <br /> yes I No N/A. <br /> _ <br /> Di enser— E—Ey- <br /> Dispenser <br /> enser— 1/2 El E-111 <br /> —3/4 � Di enser— <br /> Dispenser—5/6 Di enser— ❑ ❑ <br /> Dispenser 7/8 Di enser— <br /> :,�>...�,�. <br /> PAPERWORK INSPECTION - <br /> 9. Monitoring System Certification was completed within th_e a t 12 months? 11-29-2011 <br /> 11-29-2011 <br /> 10. Line Leak Detectors were tested/certified within the past 12 n onths? 11-29-2011 <br /> 11. Spill bucket(containment structure testin com leted within he ast 12 months? <br /> 12. Line tightness testing coin leted within the re uired time frac e? 2-11-2011 <br /> 13. Secondary containment tests corn leted within the re uired time frame? <br /> 14. Enhanced Leak Detection completed within the re uired time frame? <br /> 15. Other required testing/maintenance was completed within required time frame? List test/maintenance items below.) <br /> Describe Test/Maintenance:Air guality St 27&30 <br /> --- 12-22-2011 <br /> Describe Test/Maintenance: :._ <br /> :. ... 777, Yes No N/A <br /> FACILITY EMPLOYGI TRAINING <br /> i6. Have all facilit em to ees received the re uired on-the-ob t ainin within the past ear? <br /> 17. Have all facilit em to ees hired within the ast 30 da s rcce ved the required on-the-job training. <br /> .? <br /> Note: Explain any"No" answers in the"Comments"section on the llowing page.Those issues require corrective action from <br /> the UST owner/operator. 9/26/0- <br /> UN-057-1/2 www.unidors.or <br />
The URL can be used to link to this page
Your browser does not support the video tag.