My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOCKEFORD
>
1225
>
2300 - Underground Storage Tank Program
>
PR0231350
>
COMPLIANCE INFO_2009-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 1:38:11 PM
Creation date
6/3/2020 9:47:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2015
RECORD_ID
PR0231350
PE
2361
FACILITY_ID
FA0003690
FACILITY_NAME
LODI FOOD & LIQUOR*
STREET_NUMBER
1225
Direction
W
STREET_NAME
LOCKEFORD
STREET_TYPE
ST
City
LODI
Zip
95240
APN
03710002
CURRENT_STATUS
01
SITE_LOCATION
1225 W LOCKEFORD ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231350_1225 W LOCKEFORD_2009-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
481
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STO GE TANK SYSTEM <br /> DESIGNATED UST OPERATORMNTHLY INSPECTION REPORT <br /> Facility Name: Lodi Food & Liquor Inspection Date: .7//7 la <br /> Facility Address: 1225 Lockford Street City: Lodi, CA 95240 <br /> Name of Designated UST Operator Conducting Inspection: Z <br /> International Code Council Certification No.: �'(�a�Y :_u Expiration Date: �� fid, /� <br /> Signature: Phone: (916) 371-2380 ext. <br /> N/A=Not A licable <br /> Item MONITORING PANEL/AL RM HISTORY Yes No N/A <br /> 1. Is the monitoring system powered on and in proper operating ode? <br /> 2. Is the monitoring system not currently showing any leak alar s? ❑ <br /> 3. Is the Alarm History Report/log for the previous month avails le,and has it been reviewed by the ❑ <br /> ' Designated UST Operator? (Attach a copy of the alarm histoitv report/logreportllog to this ins ection orm.) <br /> 4. Has each alarm for the previous month been res onded to a o riatel ? " <br /> UST SYSTEM INSP CTION <br /> 5. Are tank-top containment sumps free of water,debris,and haz rdous substance? Note:If the answer to item 4 was "Yes,"skip <br /> to Item 6. Sumps where an alarm has occurred in the past month nr:rst be spected if a qualified service technician has not responded to,and <br /> ro err addressed,the cause o lire alarm.Documentation ver in a ro rate service should be attached to this report. <br /> Ye' I No Ye., No <br /> Sump Location: Suinp Location: ❑ <br /> Sum Location: Su Location: ❑ <br /> 6. Ares ill buckets(containment structures)free of water,debrisj and hazardous substance? <br /> Yes No N/A I Yes No N/A <br /> Tank 11D-87 Ta k4ID– El 11 tE <br /> Tank 2ID-91 — Ta k51D– #LJ ❑Tank 3 ID–DSLFTa k 6 ID– ❑ <br /> 7. Are under-dispenser containment areas free of water,debris,and hazardous substance? <br /> Yesl No I N/A Yes No N/A <br /> Dispenser– 1/2 Ull El I Dis enser– ❑ <br /> - Dispenser–3/4 Dis enser– U 1 ❑ 1 ❑ <br /> Dispenser–5/6 LJ Dis enser– ❑ -El- <br /> Dispenser <br /> Dis enser–7/8LJ:iE IDis enser– ❑ <br /> 8. Leak detection is properly located within under-dis enser containment. <br /> Yes I No N/A I es I No N/A <br /> Dispenser– 1/2 Dist enser– I ❑ ❑ <br /> Dispenser–3/4 El Dist enser– I ❑ ❑ ' <br /> Dispenser–5/6 Erl. Dist enser– El I ❑ ❑ <br /> Dispenser–7/8 ElDis enser– ❑ ❑ ❑ <br /> PAPERWORK INSPECTION Yes No N/A Date Done <br /> 9. MonitoringSystem Certification was completed within the past 2 months? 11-29-2011 <br /> 10. Line Leak Detectors were tested/certified within the past 12 moths? 11-29-2011 <br /> 11. Spill bucket containment structure)testingcompleted within th past 12 months? 11-29-2011 <br /> 12. Line tightness testingcompleted within the required time frame? <br /> 13. Seconds containment tests completed within the required time ame? 2-11-2011 <br /> 14. Enhanced Leak Detection completed within the required time fra e? <br /> 15. Other required testing/maintenance was completed within re uir d time frame? (List test/ aintenance items below.) <br /> Describe Test/Maintenance:Air Quality St 27&30 9 El 10 12-22-2011 <br /> Describe Test/Maintenance: L_J F1 10 <br /> h . <br /> FACILITY EMPLOYEE TRAIN NG Ye No N/A <br /> 16. Have all facility employees received the required on-the-job train ng within the past ear? <br /> 17. Have all facili em to ees hired within the 2ast 30 da s receive the required on-the-ob training.? ❑ <br /> Note: Explain any"No"answers in the"Comments"section on the follo ing page.Those issues require corrective action from <br /> the UST owner/operator. <br /> UN-057-1/2 www.uttidocs•org 9/26/05 <br />
The URL can be used to link to this page
Your browser does not support the video tag.