Laserfiche WebLink
Appendix VI <br />MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of <br />Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br />each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br />owner/operator. The owner/operator must submit a copy of this form to <br />the local agency regulating UST systems within 30 days of test date. <br />A. General information <br />Facility <br />N.—LODI FOOD & LIQUOR <br />Bldg. No.: <br />Site <br />Address 1225 W LOCKFORD ST <br />City: LODI CA Zip: <br />Facility Contact <br />Person- PAUL <br />Contact Phone No.: ( ) <br />Make/Model of Monitoring System: INCON <br />Date of Testing/Servicing: 11/29/2011 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropirlate boxes to indicate s ecifle a ui ment ins ectad/serviced: <br />Tank ID: 87 <br />Tank ID: 91 <br />® In -Tank Gauging Probe. Model: MAG <br />® In -Tank Gauging Probe. Model: MAG <br />® Annular Space or Vault Sensor. Model: EIS <br />❑ Annular Space or Vault Sensor, Model: SPLIT W DSL <br />® Piping Sump / Trench Sensor(s). Model: ULS <br />® Piping Sump / Trench Sensor(s), Model: ULS <br />❑ Fill Sump Sensor(s). Model: <br />❑ Fill Sump Sensor(s). Model: <br />® Mechanical Line Leak Detector. Model: 99LD 2000 <br />® Mechanical Line Leak Detector. Model: 99LD 2000 <br />❑ Electronic Line Leak Detector. Model: <br />❑ Electronic Line Leak Detector. Model: <br />❑ Tank Overfill / High -Level Sensor. Model: <br />❑ Tank Overfill / High -Level Sensor. Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: DSL <br />Tank ID: NA <br />® In -Tank Gauging Probe. Model: MAG <br />❑ In -Tank Gauging Probe. Model: <br />® Annular Space or Vault Sensor. Model: EIS <br />❑ Annular Space or Vault Sensor. Model: <br />® Piping Sump / Trench Sensor(s). Model: ULS <br />❑ Piping Sump / Trench Sensor(s). Model: <br />❑ Fill Sump Sensor(s). Model: <br />❑ Fill Sump Sensor(s). Model: <br />® Mechanical Line Leak Detector. Model: 99LD 2000 <br />❑ Mechanical Line Leak Detector. Model: <br />❑ Electronic Line Leak Detector. Model: <br />❑ Electronic Line Leak Detector. Model: <br />❑ Tank Overfill / High -Level Sensor. Model: <br />❑ Tank Overfill / High -Level Sensor. Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ID: 1-2 <br />Dispenser ID: 5-6 <br />® Dispenser Containment Sensor(s). Model: ULS <br />® Dispenser Containment Sensor(s). Model: ULS <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 3-4 <br />Dispenser ID: 7-8 <br />® Dispenser Containment Sensor(s). Model: ULS <br />® Dispenser Containment Sensor(s). Model: ULS <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment <br />❑ Dispenser Containment Sensor(s). Model: <br />Sensor(s). Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was Inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br />and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check a// that apply): ❑ System set-up <br />❑ Alarm history report <br />Technician Name (print): DAVE WINKLER <br />Signature: _-,13 <br />Certification No.: 5263373 -UT <br />License No: 08-1739 <br />Testing Company Name: AFFORDA-TEST <br />Phone No. (209) 744-0113 <br />Testing Company Address: 416 2 STREET GALT, CA 95632 <br />Date of Testing/Servicing: 11-29-2011 <br />Monitoring System Certification <br />Page 1 of 4 2/21/07 <br />