Laserfiche WebLink
SWRCB, January 2006 <br />Spill Bucket Testing Report Form <br />This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and <br />printouts from tests (f applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. <br />1. FACILITY INFORMATION <br />Facility Name: LODI FOOD & LIQUOR Date of Testing: 11-29-2011 <br />Facility Address: 1225 W LOCKFORD ST LODI CA <br />Facility Contact: PAUL Phone: <br />Date Local Agency Was Notified of Testing: <br />Name of Local Agency Inspector (if present during testing): ARIS <br />2. TESTING CONTRACTOR INFORMATION <br />Company Name: AFFORDA TEST 4162 nd Street Gait, CA 95632 (209) 744-0112 Fax: (209) 744-0116 <br />Technician Conducting Test: ❑ Lyle D. Nimmo ❑ Zane A. Nimmo ® David A. Winkler ❑ Felix G. Ramirez <br />5249115 -UT 5263322 -UT 5263373 -UT 5273934 -UT <br />Credentials': ® ICC Service Tech. ® SWRCB Tank Tester <br />3. SPILL BUCKET TESTING INFORMATION <br />Test Method Used: ® Hydrostatic ❑ Vacuum ❑ Other <br />Test Equipment Used: h20 and tape measure <br />Identify Spill Bucket (By Tank 1 87 2 91 <br />Number, Stored Product, etc. <br />Equipment Resolution: 1/16 <br />3 DSL 4 <br />Bucket Installation Type: ®Direct Bury <br />❑ Contained in Sump <br />®Direct Bury <br />❑ Contained in Sump <br />® Direct Bury <br />❑ Contained in <br />Sump <br />❑ Direct Bury <br />❑ Contained in <br />Sum <br />Bucket Diameter: 11 <br />11 <br />11 <br />Bucket Depth: 12 <br />11 <br />10 <br />Wait time between applying <br />vacuum/water and start of test: <br />Test Start Time (TI): 9 <br />9 <br />9 <br />Initial Reading (111): 11 <br />11 <br />9 <br />Test End Time (TF): 10 <br />10 <br />10 <br />Final Reading (RF): 11 <br />11 <br />9 <br />Test Duration (TF — TI): IHR <br />IHR <br />IHR <br />Change in Reading (RF - RI): 0 <br />0 <br />0 <br />Pass/Fail Threshold or 1/16 <br />Criteria: <br />1/16 <br />1/16 <br />Test Result: ® Pass ❑ Fail <br />®'Pass ❑ Fail <br />1 Z Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br />I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. <br />Technician's Signature: Vlz�Date 11-29-2011 <br />' State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements <br />may be more stringent. <br />