7. UNDER-DISPENSERCONTAINMENT(IJJD )j ff j! iC <br /> FTTest mec 110I:)cvcloped By: ❑t.1 )C Manufacturer Z lndustr,Standard ❑ Professional Engineer <br /> j ❑ Other{s/rcc tP�) <br /> __..._._ _...._...._.._.............__. __ .._... . ....................... ......._...._. ........ .___... .. _ <br /> Test Method Used: El Pressure ❑ Vacuum TTvdrostatic <br /> ❑ <br /> _ Other 6tti) <br /> _...... _...... <br /> g Test I:quipnicnt Used: 1NCO-N TS-STS Equipment Resolution:0.0001. <br /> 1.t1}C.# 1/2 11 DC f4 314 Li1)C##5/6 UDC:##7/8 <br /> f. UDC'Man utacturer: UNKNOWN UNKNOWN UNKNOWN UNKNOWN <br /> _ �_ w ._...._.. _ __. <br /> U Material: 1°`G FG FG 1±G <br /> u ____ _..._._.._ _..._ ......___.__. ..�.._.......__..._ ...___ �r_ <br /> UD f)epth_ 28" 28" 28" 28" <br /> _ _...._........._.._.. _. <br /> ITeig-ht from UDC Bottom to Top 7„ 7" 7„ 71' <br /> ¢ of l-li rhe st jpm „Penetration: <br /> _._.......... <br /> � _.._....._......... <br /> height front.UDC Bottom to N/A N/A N/A N/A <br /> Lowest Electrical Penetration: <br /> _ _I_ <br /> __ __. _. _. .............. <br /> I C''ondttzon crT t DC prier to FAIR FAIR FAIR FAIR <br /> I? testing. _ <br /> I Portion of'UDC fated' 10" 10" 1T}" 10" <br /> _......_......._.__m____ _..,,._ _....__....._.._..._ _.......�. __w____....._...,. <br /> i) <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ®Yes❑No[I NA E]Y,,❑No❑NA Z Yes❑No❑NA 0 Yes❑No❑NA <br /> roclttct and water)`?` <br /> N 'Turbine shutdown rig .S.c tune <br /> Is system programmed for trail- Z YesNo❑NA ®Yes❑No❑NA ®Yes❑No❑NA ®Yrs❑No(❑NA <br /> safe shutdown?" <br /> _ _. ........... <br /> Wa, Fail-safe verified riTiect to be <br /> o Brat€anal? Z Yes n No F1 NA ®Yee❑No®NA Yes❑No n NA Z Yes❑No®NA <br /> i Wait time between applying <br /> lj press ure/'vacuung/water and S MIN 5 MIN 5 MIN5 MIN <br /> z <br /> startin f test <br /> Test Start Time: 1:57 1.57 1:57 1:57 <br /> _ .__. _..___ _ _ _ <br /> x Initial Reading(Ri): _ t).5297 09825 2.3925 3.0864 <br /> Test End Time: 2:12 2:12 2:12 2,12 <br /> Final Reading(R0: 0.5305 0.9826 2.3919 3,0876 <br /> Test Duration: 15 MIN 15 MIN 15 MIN 15 MIN <br /> Change in Reading(R R� 0.0003 0 0001 0 0006 0.0012 <br /> __. ..__. . ._..._ ......... _.... . _ _ _ <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 0.002 <br /> Test Result. Psss <br /> l ail Piss 1'a�il Pam ©Fail Pass Fail" <br /> Wats sensor removed for testing:' E Yes(❑No Ej NA E Yes❑No❑NA ®Yes❑No ED NA Yrs 0 No❑NA <br /> Was sensor properly replaced and <br /> verified functional atter testing? <br /> E Yes❑No❑NA Yes[:1 No❑NA � Z Yes E]No❑NA �Yes❑No❑NA <br /> Ct3IT MICIAS ttnc/rar/c rraJnz tr8crtrrrtl e>n r /)(t[r t rrzrxc%err urr Per to tin Tcant/rc«>rsrrat�rzc/eiJ fr�1/rrac up for_fade fadedtests) <br /> ' If the entire depth of the IJI)C is not tested,specify how-much was tested. Ifthe answer to qtly ofthe questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCTI LG-160) <br /> `i ccsndazy Containment Test Results 5 of 6 <br /> _ __ ---•-._.... .. ......_._......... _.._........ ........_. ,v ...... _ _ _... _. ...E ... .. ._... .... ._ .... <br />