11TATE OF CALIFORNIA ,•y. <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION• FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM '�^�•�'' <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY SITE <br /> ONE REM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK,CLOSURE ❑ • TANK REMO 01 <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: <br /> 1. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK L D.sI 13. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAY/YEAR) 0. TANK CAPACITY IN GALLONS: ` 0 <br /> II.TANK CONTENTS IFA-I IS MARKED.COMPLETE ITEM C. REGULAR <br /> �(�•• <br /> A I MOTOR VEHICLE FUEL ❑ 4 OIL B. C. L,G'ti 1aUNLEA ED ❑ 1 DIESEL ❑ 6 AVIATION GAS <br /> ❑ 2 PETROLEUM CD 80 EMPTY 1 PRODUCT 1b PREMIUM 4 GASAHOL 7 METHANOL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 2 WASTE a UNLEADED 5 JET FUEL ❑ <br /> ❑ LEAD99 OTHER (DESCRIBE IN ITEM 0. BELOW) <br /> 0. IF(A.1)IS NOT MARKED. ENTER NAME OF SUBSTANCE STORED C.A.S.i <br /> 111. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.B.AND C.AND ALL THAT APPLIES IN BOX 0 AND E <br /> A. TYPE OF lL`d I ABLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER 17 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALL ❑ 4 SECONDARY CONTAINMENT (VAULTED TANK) ❑ 99 OTHER <br /> 8. TANK ❑ 1 BARE STEEL ❑ 2 STAINLESS STEEL 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W/FRP <br /> (Primary Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN 99 OTHER <br /> ❑ 1 RUBBER LINED F-12 ALKYO LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> C INTERIOR <br /> LINING ❑ 5 GLASS LINING ❑ 6 UNLINED ❑ 95 UNKNOWN 99 OTHER V C, <br /> IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES&NO_ <br /> 0.CORROSION ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑j 5 CATHODIC PROTECTION 21 9/ NONE ❑95 UNKNOWN 99 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) _ <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A(o PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> S. CONSTRUCTION A U 1 SINGLE WALL A U 2 DOUBLE WALL A U 'B LINED TRENCH A U 95 UNKNOWN A U 90 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)AU04 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U 6 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A V 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION is1 AUTOMATIC LINE LEAK DETECTOq ,8 2 LINE TIGHTNESS TESTING ❑ 1 OERST ❑`o OTHER <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK 2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING ❑ 4 AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br /> 6 TANK TESTING 7 INTERSTITIAL MONITORING 91 NONE 95 UNKNOWN 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MO/DAY/YR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING GALLONS INERT MATERIAL? YES a NO❑ <br /> THIS FORM H EOMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> APPUCANTSNAME <br /> (m a SIGMA I DATE <br /> LOCAL AGENC USE ONLY THE STATE I.D.NUMBERS COMPOSED OF THE FOUR NUMBERS BELOW <br /> STATE LD.# Mfl <br /> COUNTY# JURISDICTION# FACILITY# ' TANK <br /> 3 2 li 3 1 O / IF <br /> PERMIT NUMBER PERMIT APPROVED SY/DATE PERMIT EXPIRATION DATE <br /> J, <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. <br /> FORM 8 (12.91) FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE UNDERGROUND STORAGE TANK REGULATIONS <br /> PORs67t6'.Rs <br />